Re: Tek/HP/Etc chat server
I can choose not to participate.
toggle quoted message
Show quoted text
Sean On Wed, Jan 5, 2022 at 10:26 AM, cheater cheater wrote: The owner of every forum is exempt from every rule they set, and you |
Re: Tek/HP/Etc chat server
The owner of every forum is exempt from every rule they set, and you
can't do anything about it. This forum, unlike others, states it outright. I put this rule in explicitly so people who make trouble don't start contrived technical legal babble arguments about what I may or may not do when I'm moderating the platform. This prevents any "gotcha" moments. This sort of trolling strategy comes up often enough on well populated forums that it's a real time waster. For example, let's say someone said a racist cuss word. I'll kick them off saying "you're getting kicked off because you said X". Then they'll start arguing that I should kick myself off, or something equally stupid. I've had this happen a million times and I can't be bothered with that. Hence rule 6. On Tue, Jan 4, 2022 at 7:32 AM Sean Turner via groups.io <sdturne@...> wrote:
|
Re: Dead 54720D
I was thinking about exactly the same. Do you want to compare to see where the check sume is stored ??
W ?roda, 5 stycznia 2022, 03:26:37 UTC, Mike Walters <mike@...> napisa?(-a):
Does anyone have a copy of the 54720 or 54710 firmware disk? If I could take a look at that, I can probably figure out how to make a 54717a eeprom image for you. On Tue, 4 Jan 2022 at 16:55, Arkadiusz Gibes via groups.io <arkadiusz.gibes=[email protected]> wrote: > > I already found the 54712 eeprom image that you shared. Do you have any possibility, to download same firmware from the other unit ? I would like to compare. I have one 54712 unit, but still don't have programmer. > > W wtorek, 4 stycznia 2022, 16:46:54 UTC, Ovidiu Popa [Business] <ovidiu.popa@...> napisa?(-a): > > > Sorry, no, I gave up and wrote off the 54720D. I have too many scopes anyway, from 100MHz to 50GHz, not enough incentive to spend more time on this. Meantime, watching for a 54717A, ideally someone owning one could dump the EEPROM. I know if I'd get one, this would be the first thing I'd do, this HP money grabbing calibration abomination has to end. > > If someone wants to pick up, I can forward the 54712A EEPROM binary. > |
Re: Dead 54720D
Does anyone have a copy of the 54720 or 54710 firmware disk? If I
could take a look at that, I can probably figure out how to make a 54717a eeprom image for you. On Tue, 4 Jan 2022 at 16:55, Arkadiusz Gibes via groups.io <arkadiusz.gibes@...> wrote:
|
Re: 98034A HPIB adaptor for 9825
¿ªÔÆÌåÓýHP 85A, that's what it was.? After 3 and a half decades it took me a while to recall.? ? ? ? ? Jim Sent from my T-Mobile 4G LTE Device -------- Original message -------- From: Paul Berger <phb.hfx@...> Date: 1/4/22 2:58 PM (GMT-08:00) Subject: Re: [HP-Agilent-Keysight-equipment] 98034A HPIB adaptor for 9825 On 2022-01-04 6:16 p.m., Jim Ford wrote: > Hmmmm.... We used something similar at Varian Beverly Microwave > Division in 1986.? I can't remember the model number, but like the > 9825, what we used was more than a calculator and less than a > full-blown computer.? Ours had an LCD screen, though.? We used it to > calculate pi pad resistor values.? Anybody remember the model no?? ? ? > ? ? ? ? ? ? ?Jim Ford > > > The only thing from HP I can think of from around that time? that had a LCD screen would have been the portable 45710A or portable plus 45711B both of which had MSDOS in ROM.? There was also the larger Integral which had a LCD like screen and ran HP-UX from ROM. Paul. |
Re: 98034A HPIB adaptor for 9825
On 2022-01-04 6:16 p.m., Jim Ford wrote:
Hmmmm.... We used something similar at Varian Beverly Microwave Division in 1986.? I can't remember the model number, but like the 9825, what we used was more than a calculator and less than a full-blown computer.? Ours had an LCD screen, though.? We used it to calculate pi pad resistor values.? Anybody remember the model no?? ? ? ? ? ? ? ? ? ?Jim FordThe only thing from HP I can think of from around that time? that had a LCD screen would have been the portable 45710A or portable plus 45711B both of which had MSDOS in ROM.? There was also the larger Integral which had a LCD like screen and ran HP-UX from ROM. Paul. |
Re: 98034A HPIB adaptor for 9825
¿ªÔÆÌåÓýHmmmm.... We used something similar at Varian Beverly Microwave Division in 1986.? I can't remember the model number, but like the 9825, what we used was more than a calculator and less than a full-blown computer.? Ours had an LCD screen, though.? We used it to calculate pi pad resistor values.? Anybody remember the model no?? ? ? ? ? ? ? ? ? ?Jim Ford Sent from my T-Mobile 4G LTE Device -------- Original message -------- From: "nigel adams via groups.io" <bristol.rell6l@...> Date: 1/4/22 1:58 PM (GMT-08:00) Subject: [HP-Agilent-Keysight-equipment] 98034A HPIB adaptor for 9825 I have unearthed a 98034A HPIB adaptor for the 9825 calculator. I will also post in the for sale group but have seen people discuss such items on here to so hope admins will allow this indiscretion. I don¡¯t have anything else related to this unit - although there appears to be plenty on the web. Looks in good condition - although I am unable to test it. If anyone would like to make me an offer for it, based in uk. Regards Nigel by banging a nail into a piece of wood... |
98034A HPIB adaptor for 9825
All,
I have unearthed a 98034A HPIB adaptor for the 9825 calculator. I will also post in the for sale group but have seen people discuss such items on here to so hope admins will allow this indiscretion. I don¡¯t have anything else related to this unit - although there appears to be plenty on the web. Looks in good condition - although I am unable to test it. If anyone would like to make me an offer for it, based in uk. Regards Nigel Sent from my iPad by banging a nail into a piece of wood... |
HP8903A serial prefix 2414A service manual
Hi all! I have an 8903A (with faults) and have been using the online edition of the 8903A manual (covering 1942A-2016A) fine for the CPU/latch/oscillator boards, but in the next stage of fault finding I need to look at the A6 oscillator amps / attenuators board and this is significantly different from the one illustrated (it has 3 relays). There is an online?8903B manual for 2450A to 2948A. Board is 08903-60105? The one in the 8903A manual?is 08903-60008 and the one in the 8903B is very different (08903-60132) the latter uses DACs as programmable amplifiers feeding signal in as VREF, the one I have appears to use JFETs to switch Rs in an opamp circuit. Does anyone?know of the existence of a manual covering?2414A - or possibly revisions sheets explaining what changed? Would also be interested to know why... but that is probably too much to hope for!? If a real manual rather than electronic it would be the A6 board?I would like to know about (service sheets 10 & 11) even just schematics. Alan Bain P.S. Faults so far include dead F8 CPU, a mask ROM 4 which output data when OE was high causing RAM test errors, leaky caps in sample and hold (C45/C39). Leaky electrolytics on A3 board on supply rails.To fix remains oscillator distortion too high; output level too high when 3V RMS from osc board. AC RMS meter?seems to work, notch filter not tested. |
Not H-P, But definately about scopes: WTB Philips PM-3000/3010
¿ªÔÆÌåÓýMini oscilloscopes are one of my
collecting and restoration interests.? I am looking for a Philps
PM-3000 or 3010. Need not be working, completeness is
important.? AND- I am still looking for a Tektronix 224 handheld
scope at a reasonable price. Thanks, |
Added album HP-5347/48A and HP-5361A Coffee mug
#photo-notice
[email protected] Notification
Jeremy Nichols <jn6wfo@...> added the album HP-5347/48A and HP-5361A Coffee mug: ¡°Two instruments in one.¡± Promotional item from the 1970s. Images appear when hot liquid is poured into the mug. My error was putting the mug in the microwave oven. Now the images are permanent. Free for shipping. |
Re: Just wanted to point out that the HP3851A is pretty cool after all these years..
On 1/3/22 7:11 AM, Anders wrote:
I am testing a battery protector for LiFePO4. It measures individual cell voltages from a stack of four cells and cuts out if any of the cells fall under or goes over a preset value. The 44702 + 44711 lets me measure all cell voltages and the voltage over the shunt over time when testing charging and discharging. Data is sent over GPIB to Excel.I picked up one of these not long ago, largely because of the great info on your page. I've not gotten any modules for it yet, though. -Dave -- Dave McGuire, AK4HZ New Kensington, PA |
HP 8663A Keycode Stimulus Diagnostic
The keycode assembly on my HP 8663A is failing to interrupt the microprocessor. To narrow down the fault to an IC, I was hoping to use signature analysis on the keycode assembly. In the manual I have (2234A to 2927A, vol 2) under service sheet BD9 there is a "KEYCODE STIMULUS DIAGNOSTIC", which states the following:
This test stimulates the A2A1 Keycode Assembly for signature analysis testing. Refer to Service Sheets 61 and 62 troubleshooting information for procedures and the use of this Diagnostic. However, when I refer to the these service sheets in vol 4 (same serial prefix range) I don't see any signature analysis information. Each service sheet contains a block diagram, a component locator and a schematic, but I don't see SA information on any of these. I was expecting to see 4-digit hex sequences by various nodes in the schematics. Or, I was expecting to see something like the signature analysis table in the "SIGNATURE ANALYSIS I/O DIAGNOSTIC". What am I missing? |
Re: Attenuator calibration hp 54503a
tmillermdems
¿ªÔÆÌåÓýWhat did you use to make the connection? On 1/4/2022 4:11 AM, paul larner wrote:
Hi all,ive an old hp 545o3a scope,i was looking at the callibrator signal from my tek 2430 with this,it states on the front panel that it outputs 400mv into 1megohm and 200mv into 50 ohms,when set to 50 ohm input on my hp scope it reads about double! that,does it need the attenuators calibrating?,if so how do you do it?,Tia. |
Re: Dead 54720D
I already found the 54712 eeprom image that you shared. Do you have any possibility, to download same firmware from the other unit ? I would like to compare. I have one 54712 unit, but still don't have programmer.?
W wtorek, 4 stycznia 2022, 16:46:54 UTC, Ovidiu Popa [Business] <ovidiu.popa@...> napisa?(-a):
Sorry, no, I gave up and wrote off the 54720D. I have too many scopes anyway, from 100MHz to 50GHz, not enough incentive to spend more time on this. Meantime, watching for a 54717A, ideally someone owning one could dump the EEPROM. I know if I'd get one, this would be the first thing I'd do, this HP money grabbing calibration abomination has to end. If someone wants to pick up, I can forward the 54712A EEPROM binary. |
Re: Dead 54720D
Sorry, no, I gave up and wrote off the 54720D. I have too many scopes anyway, from 100MHz to 50GHz, not enough incentive to spend more time on this. Meantime, watching for a 54717A, ideally someone owning one could dump the EEPROM. I know if I'd get one, this would be the first thing I'd do, this HP money grabbing calibration abomination has to end.
If someone wants to pick up, I can forward the 54712A EEPROM binary. |
Re: Attenuator calibration hp 54503a
its sorted,when i first got this it had a bad psu,recapping the psu got it going,at the time i didnt have suitable load resistors to set the 5.2v output,when i finaly checked it was at about 5.8v,anyway i set it to 5.2 and recalibrated the scope,it now seems to be spot on,i can only think the first calibration i did when the psu output was too high caused the bad readings,after a recal its now fine.
|
Attenuator calibration hp 54503a
Hi all,ive an old hp 545o3a scope,i was looking at the callibrator signal from my tek 2430 with this,it states on the front panel that it outputs 400mv into 1megohm and 200mv into 50 ohms,when set to 50 ohm input on my hp scope it reads about double! that,does it need the attenuators calibrating?,if so how do you do it?,Tia.
|