开云体育

Date

Re: Introduction

Robert Middleton
 

开云体育

?
----- Original Message -----
Sent: Sunday, May 16, 2004 11:18 AM
Subject: Re: [hp_agilent_equipment] Introduction

Hello Jack.
?
This is Robert.?I have a list of H.P. Oscilliscopes I am looking for. Perhaps you might have a few of them or perhaps you could point me in the direction of where I can locate them? Enclosed is my list and I will keep an eye out for manuals you need. Thanks.
?
Respectfully, Robert
?
p.s. Below is my list of H.P. oscilliscopes;
?
OS-121A/USM-140
OS-82A/USM-105
OS-121C/USM-140
OS-121D/USM-140
?
?
----- Original Message -----
From: Jack Crone
Sent: Thursday, May 13, 2004 10:07 PM
Subject: [hp_agilent_equipment] Introduction

Greetings All,

I am a new member of the group and am looking forward to an enjoyable
time here.

I have a large inventory of HP boat anchors which I want to dispose of.
Some I want to sell as functional units, others might get parted out if
there is any market for these parts. There are over 60 units consisting
of these models: 130C, 140A, 1900A, 200CD, 214A, 302B, 342A, 400D, 400H,
411A, 415B, 428A, 431B, 5210A, 523C, 606A, 608C, 608D, 612A, 614A, 616A,
618B, 626A, 694A, 851B, 8690A, and probably a few others.

Any suggestions for disposing of this would be appreciated. I also need
manuals for most models and there are just too many to buy them. I think
that there are downloadable manuals for the equivalent military units
but I don't know the military model numbers. Is there a cross reference
list available?

Thanks,

Jack




Re: Introduction

Robert Middleton
 

开云体育

Hello Jack.
?
This is Robert.?I have a list of H.P. Oscilliscopes I am looking for. Perhaps you might have a few of them or perhaps you could point me in the direction of where I can locate them? Enclosed is my list and I will keep an eye out for manuals you need. Thanks.
?
Respectfully, Robert
?
p.s. Below is my list of H.P. oscilliscopes;
?
OS-121A/USM-140
OS-82A/USM-105
OS-121C/USM-140
OS-121D/USM-140
?
?

----- Original Message -----
From: Jack Crone
Sent: Thursday, May 13, 2004 10:07 PM
Subject: [hp_agilent_equipment] Introduction

Greetings All,

I am a new member of the group and am looking forward to an enjoyable
time here.

I have a large inventory of HP boat anchors which I want to dispose of.
Some I want to sell as functional units, others might get parted out if
there is any market for these parts. There are over 60 units consisting
of these models: 130C, 140A, 1900A, 200CD, 214A, 302B, 342A, 400D, 400H,
411A, 415B, 428A, 431B, 5210A, 523C, 606A, 608C, 608D, 612A, 614A, 616A,
618B, 626A, 694A, 851B, 8690A, and probably a few others.

Any suggestions for disposing of this would be appreciated. I also need
manuals for most models and there are just too many to buy them. I think
that there are downloadable manuals for the equivalent military units
but I don't know the military model numbers. Is there a cross reference
list available?

Thanks,

Jack



Re: Introduction

 

开云体育

I'm in Tulsa, OK..

----- Original Message -----
From: Jack Crone
Sent: Saturday, May 15, 2004 4:30 PM
Subject: [hp_agilent_equipment] Re: Introduction

Hank WD5JFR wrote:
> Jack
> Where are you located?
> tnx

I'm in Klamath Falls, Oregon. That is south-central Oregon, 20 miles
from the California border and light-years from any recognized civilzation.

Jack



Re: Introduction

 

Hank WD5JFR wrote:
Jack
Where are you located?
tnx
I'm in Klamath Falls, Oregon. That is south-central Oregon, 20 miles from the California border and light-years from any recognized civilzation.

Jack


Re: Introduction

 

开云体育

Jack
Where are you located?
tnx
Hank WD5JFR

----- Original Message -----
From: Jack Crone
Sent: Friday, May 14, 2004 12:07 AM
Subject: [hp_agilent_equipment] Introduction

Greetings All,

I am a new member of the group and am looking forward to an enjoyable
time here.

I have a large inventory of HP boat anchors which I want to dispose of.
Some I want to sell as functional units, others might get parted out if
there is any market for these parts. There are over 60 units consisting
of these models: 130C, 140A, 1900A, 200CD, 214A, 302B, 342A, 400D, 400H,
411A, 415B, 428A, 431B, 5210A, 523C, 606A, 608C, 608D, 612A, 614A, 616A,
618B, 626A, 694A, 851B, 8690A, and probably a few others.

Any suggestions for disposing of this would be appreciated. I also need
manuals for most models and there are just too many to buy them. I think
that there are downloadable manuals for the equivalent military units
but I don't know the military model numbers. Is there a cross reference
list available?

Thanks,

Jack



Introduction

 

Greetings All,

I am a new member of the group and am looking forward to an enjoyable time here.

I have a large inventory of HP boat anchors which I want to dispose of. Some I want to sell as functional units, others might get parted out if there is any market for these parts. There are over 60 units consisting of these models: 130C, 140A, 1900A, 200CD, 214A, 302B, 342A, 400D, 400H, 411A, 415B, 428A, 431B, 5210A, 523C, 606A, 608C, 608D, 612A, 614A, 616A, 618B, 626A, 694A, 851B, 8690A, and probably a few others.

Any suggestions for disposing of this would be appreciated. I also need manuals for most models and there are just too many to buy them. I think that there are downloadable manuals for the equivalent military units but I don't know the military model numbers. Is there a cross reference list available?

Thanks,

Jack


HP 3310A Function Generator - Problem

David Jarman
 

I managed to switch off and on my trusty HP 3310A yesterday while it
was connected to an audio system (not good practise!) and it now
refuses to generate a signal from the low/high outputs. The mains
indicator light comes on and the fuse appears OK.

I don't have a circuit diagram. Can anyone help me to get my 3310A
operational again please?

Thanks in anticipation.

David Jarman


follow-up - HP 3439A

computeruser04
 

The HP 3439A has been repaired. It was C8 on A9 that had failed.
I then zeroed the readout it using a calibration procedure found at
.
Thanks to everyone who replied. I also have a service manual
on the way to me from Joe VE7LBI.

Question - I zero the readout after a 30minute warmup. All ranges
read 0000 with the + & - flashing alternately. The Int Check -8000
is also set per the precedure. It will stay like that (zeroed) all
day. If I turn it off then back on the next day - the zero
calibration is off - not by much - sometimes +0001 or -0002. I can
zero it again - and it will stay like that all day. Is this normal
or am I being anal about a +35 year old instrument?

Thank
BL



--- In hp_agilent_equipment@..., "computeruser04"
<computeruser@s...> wrote:
Hello All
I was just given an old HP 3439A Digital Voltmeter to play with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a schematic
and found nothing. Really, like others have said here before, its
the challenge to see if I can get it functioning, so any info about
it is appreciated.
Thanks

BL


Re: Manual Wanted

 

开云体育

Hello Robin
I have operators book scanned-will You have them uploaded?
??????????? Best Regards
????????????????????????????? Hardy

----- Original Message -----
Sent: Thursday, May 06, 2004 10:00 PM
Subject: [hp_agilent_equipment] Manual Wanted

Hi,
Has anyone got a manual that I can copy, scan or whatever for a HP
1740A?? Or point me towards where I can download one?

All costs re-imbursed.

Regards

Robin
--
Robin Birch



Re: Manual Wanted

 

Original Message:
Date: Thu, 6 May 2004 21:00:54 +0100
From: Robin Birch <robinb@...>
Subject: Manual Wanted

Hi,
Has anyone got a manual that I can copy, scan or whatever for a HP
1740A? Or point me towards where I can download one?

All costs re-imbursed.

Regards

Robin
--
Robin Birch


Robin,

I have bunches of HP manuals, at: .

For the 1740A, it loos like all I have is the operator's guides, not a service manual.

I think ONE of the ones that I have might also be downloadable from agilent.com .


Good luck!

Tom Gootee

tomg@...


Manual Wanted

Robin Birch
 

Hi,
Has anyone got a manual that I can copy, scan or whatever for a HP 1740A? Or point me towards where I can download one?

All costs re-imbursed.

Regards

Robin
--
Robin Birch


Re: HP 3439A

Joseph Orgnero
 

Sorry, it was a typo, I should have typed 3440. The manual is operating
and service with schematics.
My e-mail is:
joseph@...
Thank you

----- Original Message -----
From: "computeruser04" <computeruser@...>
To: <hp_agilent_equipment@...>
Sent: 02 May 2004 11:53 AM
Subject: [hp_agilent_equipment] Re: HP 3439A


Joe
I am interested in the manual if it is a service manual with
a schematic. You say it is the same as the 3449 (typo?)
Is it the same as the 3439 except for the sampe rate?
If so I am interested. leave me an email or web address
Thanks
BL


--- In hp_agilent_equipment@..., "Joseph Orgnero"
<joseph@p...> wrote:
Jorgen,
I have an original manual for the HP 3440A voltmeter, which is the
same
as the 3449 except for the sample rate, cost U$S 12.00 plus
shipping.
Let me know if interested.
Thank you.
Joe Orgnero VE7LBI
----- Original Message -----
From: "Jorgen Lund-Nielsen" <dj0ud@w...>
To: <hp_agilent_equipment@...>
Sent: 01 May 2004 06:05 PM
Subject: [hp_agilent_equipment] Re: HP 3439A


--- In hp_agilent_equipment@..., "computeruser04"
<computeruser@s...> wrote:
Hello All
I was just given an old HP 3439A Digital Voltmeter to play
with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a
schematic
and found nothing. Really, like others have said here before,
its
the challenge to see if I can get it functioning, so any info
about
it is appreciated.
Thanks

BL
Did you check all supply voltages for ripple?
Power Supplys has to be checked first, ever!

Jorgen




Yahoo! Groups Links





------------------------ Yahoo! Groups
Sponsor ---------------------~-->
Buy Ink Cartridges or Refill Kits for your HP, Epson, Canon or Lexmark
Printer at MyInks.com. Free s/h on orders $50 or more to the US &
Canada.


---------------------------------------------------------------------~
->


Yahoo! Groups Links




Re: HP 3439A

computeruser04
 

Joe
I am interested in the manual if it is a service manual with
a schematic. You say it is the same as the 3449 (typo?)
Is it the same as the 3439 except for the sampe rate?
If so I am interested. leave me an email or web address
Thanks
BL


--- In hp_agilent_equipment@..., "Joseph Orgnero"
<joseph@p...> wrote:
Jorgen,
I have an original manual for the HP 3440A voltmeter, which is the
same
as the 3449 except for the sample rate, cost U$S 12.00 plus
shipping.
Let me know if interested.
Thank you.
Joe Orgnero VE7LBI
----- Original Message -----
From: "Jorgen Lund-Nielsen" <dj0ud@w...>
To: <hp_agilent_equipment@...>
Sent: 01 May 2004 06:05 PM
Subject: [hp_agilent_equipment] Re: HP 3439A


--- In hp_agilent_equipment@..., "computeruser04"
<computeruser@s...> wrote:
Hello All
I was just given an old HP 3439A Digital Voltmeter to play
with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a
schematic
and found nothing. Really, like others have said here before,
its
the challenge to see if I can get it functioning, so any info
about
it is appreciated.
Thanks

BL
Did you check all supply voltages for ripple?
Power Supplys has to be checked first, ever!

Jorgen




Yahoo! Groups Links




Re: HP 3439A

Joseph Orgnero
 

Jorgen,
I have an original manual for the HP 3440A voltmeter, which is the same
as the 3449 except for the sample rate, cost U$S 12.00 plus shipping.
Let me know if interested.
Thank you.
Joe Orgnero VE7LBI

----- Original Message -----
From: "Jorgen Lund-Nielsen" <dj0ud@...>
To: <hp_agilent_equipment@...>
Sent: 01 May 2004 06:05 PM
Subject: [hp_agilent_equipment] Re: HP 3439A


--- In hp_agilent_equipment@..., "computeruser04"
<computeruser@s...> wrote:
Hello All
I was just given an old HP 3439A Digital Voltmeter to play with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a schematic
and found nothing. Really, like others have said here before, its
the challenge to see if I can get it functioning, so any info about
it is appreciated.
Thanks

BL
Did you check all supply voltages for ripple?
Power Supplys has to be checked first, ever!

Jorgen




Yahoo! Groups Links




Re: HP 3439A

computeruser04
 

Ripple is about 1.5v on the 150v supplies and about .5v on the 50v
supply. This site:
has the calibration procedure for the 3439A which gave me some more
good information.
This site: mentions the
3440A which is very similar and their unit has the same symptoms:
"The nixie tubes light up, but multiple segments are on
simultaneously" so I am thinking this problem is common on these
units. Thanks for the replies so far.

BL



--- In hp_agilent_equipment@..., "Jorgen Lund-Nielsen"
<dj0ud@w...> wrote:
--- In hp_agilent_equipment@..., "computeruser04"
<computeruser@s...> wrote:
Hello All
I was just given an old HP 3439A Digital Voltmeter to play with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a schematic
and found nothing. Really, like others have said here before, its
the challenge to see if I can get it functioning, so any info
about
it is appreciated.
Thanks

BL
Did you check all supply voltages for ripple?
Power Supplys has to be checked first, ever!

Jorgen


Re: HP 3439A

 

--- In hp_agilent_equipment@..., "computeruser04"
<computeruser@s...> wrote:
Hello All
I was just given an old HP 3439A Digital Voltmeter to play with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a schematic
and found nothing. Really, like others have said here before, its
the challenge to see if I can get it functioning, so any info about
it is appreciated.
Thanks

BL
Did you check all supply voltages for ripple?
Power Supplys has to be checked first, ever!

Jorgen


Re: HP 3439A

 

开云体育

I don't know if it will make you feel any better but I have a Fairchild Model 7000, 5 1/2 digit Nixie tube?DMM? and I use it all the time.? Works perfect.? I also have a Systron Donner 6152A, 500 mHz Nixie freq. counter and it also works perfect.? I love Nixies -no reading glasses required!? The pinnacle of display technology, IMHO, ?was planar gas.? LCD displays were the downfall of modern electronics- screw low power consumption!?
?
Sorry I can't help you with the schematic.? There are many vintage manual resellers (and some free) ?out there? try:
?
?
?
?
?
?
?
?
?
?
Good Luck!

-----Original Message-----
From: computeruser04 [mailto:computeruser@...]
Sent: Saturday, May 01, 2004 11:51 AM
To: hp_agilent_equipment@...
Subject: [hp_agilent_equipment] HP 3439A

Hello All
I was just given an old HP 3439A Digital Voltmeter to play with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a schematic
and found nothing. Really, like others have said here before, its
the challenge to see if I can get it functioning, so any info about
it is appreciated.
Thanks

BL


HP 3439A

computeruser04
 

Hello All
I was just given an old HP 3439A Digital Voltmeter to play with.
It has the 3443 High Gain/Auto Range plugin. The Nixie tubes
light but display random digits. I have searched for a schematic
and found nothing. Really, like others have said here before, its
the challenge to see if I can get it functioning, so any info about
it is appreciated.
Thanks

BL


Neat document from Agilent

John Miles
 

Quite a few typos scattered throughout, but still a very interesting
historical document on HP/Agilent gear through the ages.

(36 pages, about
2 MB)

-- john KE5FX


Re: HP 8552A Service Manual Download

 

开云体育

you can find the service man. for the B version at BAMA site
Elie
?