Re: VNA Resonance Methodology

 

¿ªÔÆÌåÓý

The reflection coefficient will be close to 1 , but if you need to measure resonance you must to pay attention to phase. For this reason I said that the reactive part of Z goes to zero in resonance. There are two resonance definitions ? but to me the right is zero reactance. In this case the reflection coefficient will be a real number or phase =0 ? ¡­. its important to convert Gamma to Z in order to measure Q¡­?
Yes you can use the other port of VNA , the problem is not add more components to measurement because it will introduce more error sources. In my view is better to couple the resonant circuit with a small loop, the square of 49 is 2401 then 50*2400 ohms = 120K Ohms, you can measure this resistance with a god coupled VNA. You can also calibrate the system with the loop if you wish with other loops , a opened , a shorted , and other one with a resistor¡­ it would be very fun !! . In the other hand you don?t need to know accurate Z values , you only need to know Fo and BW to determine Q. ?

For the coils I saw in pictures ?(big ones to use in low frequency applications ) in my personal point of view the Q-meter is the best tool. This is a very low impedance source and a very high impedance voltmeter working together¡­?

When I was a child my father has a grid deep meter with coils from a few KHz to close to 300 MHz , I used it to check resonant circuits it can be combined with a frequency counter¡­ its very useful?

Since a couple of years VNA become more cheap and accessible but for this reason I think that many people tries to use it to perform all kind of measurements. VNA can give great results but fits better to measure scattering ?parameters , it was designed for that. ?


Ing. Patricio A. Greco
Taller Aeron¨¢utico de Reparaci¨®n 1B-349
Organizaci¨®n de Mantenimiento?Aeron¨¢utico de la Defensa OMAD-001
Laboratorio de Calibraci¨®n ISO 17025?AREA: RF/MW?
Gral. Mart¨ªn Rodr¨ªguez 2159
San Miguel (1663)
Buenos Aires
T: +5411-4455-2557
F: +5411-4032-0072




On 28 Nov 2024, at 17:12, jmr via <jmrhzu@...> wrote:

It's definitely going to be risky to try and measure the Q of the 49 turn solenoid with an s11 measurement using a VNA because my software program lists the magnitude of the reflection coefficient as 0.9987 at 1.45 MHz.
This would be stretching the limits of the VNA to measure with much confidence. It might still show a reasonable result but there would be a fair bit of uncertainty in the measurement.
?
If it was resonated using a parallel cap the Rp would be about 75,000 ohms at 1.45 MHz. This is also just about OK to measure at 1.45 MHz with a good VNA with a reflection measurement, but a 75,000 ohms resistance measurement is close to the limits of a good VNA at 1.45 MHz.
?
If it was resonated in series, the Rs would be just under 5 ohms at 1.45 MHz and this would be quite easy for a good VNA to measure at 1.45 MHz with very good accuracy. So I would favour this method.
?
The other good way to measure the Q would be to configure the series tuned circuit as a shunt acceptor circuit and measure the insertion loss at the resultant null at 1.45 MHz with an s21 measurement. If the Rs was about 4.8 ohms then there would be a null about 15.9 dB deep at 1.45 MHz for example. As long as the VNA ports are corrected to 50 ohms or attenuators are used to improve the VNA port match this method should measure the Q extremely accurately.
?
The 3dB bandwidth method is also viable here and it should give similar results for Q because the test frequency of 1.45MHz is going to be about 1/10th of the first self resonance frequency of the inductor. It can be fiddly to make this measurement though. I normally do this using a netbook PC to continually measure the 3dB bandwidth via GPIB. It's also possible to get a real time readout of Q on the VNA screen using this method.
?


Re: VNA Resonance Methodology

 

It's definitely going to be risky to try and measure the Q of the 49 turn solenoid with an s11 measurement using a VNA because my software program lists the magnitude of the reflection coefficient as 0.9987 at 1.45 MHz.
This would be stretching the limits of the VNA to measure with much confidence. It might still show a reasonable result but there would be a fair bit of uncertainty in the measurement.
?
If it was resonated using a parallel cap the Rp would be about 75,000 ohms at 1.45 MHz. This is also just about OK to measure at 1.45 MHz with a good VNA with a reflection measurement, but a 75,000 ohms resistance measurement is close to the limits of a good VNA at 1.45 MHz.
?
If it was resonated in series, the Rs would be just under 5 ohms at 1.45 MHz and this would be quite easy for a good VNA to measure at 1.45 MHz with very good accuracy. So I would favour this method.
?
The other good way to measure the Q would be to configure the series tuned circuit as a shunt acceptor circuit and measure the insertion loss at the resultant null at 1.45 MHz with an s21 measurement. If the Rs was about 4.8 ohms then there would be a null about 15.9 dB deep at 1.45 MHz for example. As long as the VNA ports are corrected to 50 ohms or attenuators are used to improve the VNA port match this method should measure the Q extremely accurately.
?
The 3dB bandwidth method is also viable here and it should give similar results for Q because the test frequency of 1.45MHz is going to be about 1/10th of the first self resonance frequency of the inductor. It can be fiddly to make this measurement though. I normally do this using a netbook PC to continually measure the 3dB bandwidth via GPIB. It's also possible to get a real time readout of Q on the VNA screen using this method.
?


Re: Tantalum Capacitors

 

Microdyne was strted by an engineer and a salesmmaman from Defense Eletronics, becuase they weren't interested in solid state designs. One of the owners ws still on the board when I worked there. (Hank Lin?) They used 1100 on doens of designs, and some had beeen in continuious service t BASA while I worked there. My first exposure was their various C-band receivers. They produced the best video of all nrands that United Video used in over 100 CATV headends. I ran the in house repair center,at out Delhi township system. The 1100LPR was the cheapest unit we used, but the best quality. The lowest was Scientific Atlanta, and Rockwe;;/Collins. Istead of using a couple transistors or an IC to shift the DC offset of the video, they used a lare electrolytic that often failed. This was in 1982-1986. It was obvious that they were a modifed fixed frequency military design. They used a tunable input filter, and a mechanically tuned LO fto convert directly from C band to 0 MHz. I once had 13 shipped to me from another site. They neded seven repaired. The biggest failure was the transistor in that 4GHzoscillator, with were NLA. They would make a natch of 15 for 41500 each. The 110 LPR was $800 and aile. Collins had over a six month turnaround. I often? had uits repaird and back in service within an eight hour shift. I had access to every Microdyne manual, until a few years ago, until the former Miccrodnye repiar tech retired and sold off everything. He was contracted by Microdybe to do out of warranty serviice for them.
I have an extremely rare Microdybe C band sigbnal generator that was built in ouse for final test on the production ine. I think there were aboubt a dozen built.
The 1200, 1400 and 700/1620 al used the same low phase noise snthesyser module we developed. I spent about six months working on them, and upting the design and test process afer some uncased disk capaciors became NLA.?

Enugh rambling, on here.You can contact me by email if you want to continue thee discussion, so we don't bore other memers..

On Thu, Nov 28, 2024 at 6:55?AM Michael A. Terrell via <terrell.michael.a=[email protected]> wrote:

Weren't some of these only identified by the lead length of the positive side?

On Thu, Nov 28, 2024 at 6:05?AM Dave_G0WBX via <g8kbvdave=[email protected]> wrote:

Re:-

"Some tantalum capacitors needed a small resistor of a few ohms in series with the supply voltage to limit the dV/dt and inrush current as well."


Oh Yes indeed!? In truth, I suspect all "Tantalum" cap's have a surge current limit, that if exceeded will do them damage...

In the immediate past full time day job, I ended up having to replace several SMD type 68uF/50V parts (similar to these: ) that were used to decouple an incoming +20V high current supply, that itself was switched by a relay contact.? The PSU was rated at several 100W on that rail.

I quite soon (with a bit of online research) discovered they don't tolerate surge currents that well (if at all) but could not convince our product designers of that fact, even by sending them extracts, and complete data sheets from the manufacturer they used.

(The relay contact would also pit and fail after some time too.? Another "schoolboy mistake" they made, but again not interested in mitigating.? In later versions of that product, the PSU was commanded On/Off, rather than use a relay on it's output.? It was a custom multi-rail type by then, so I guess someone else with more clout than a wholly owned subsidiary doing support and repairs could wield.)

I (like others on this list) fitted electrolytic parts instead, if they fitted inside the module (and other parts of the module, such as nearby components or the board itself were not badly damaged.)? Else, they were fitted to the outside of the case.

The data sheet from maker used (Vishay I think in that case, but I cannot be sure of that) also indicated that the larger SMD Tantalum parts, needed "annealing" after soldering to a board, to reduce/remove internal stresses built up during the SMD soldering phase, that could cause premature failure.? Something else our "engineering" types did not want to know, and/or failed to acknowledge.

In a past (much earlier) work life, I had first hand experience while working for Tek in the UK, of the great "Tantalum fitted the wrong way round issue" in such instruments as the venerable Tek 465 'scope.? Oddly, they'd often last long enough to just get past the warranty period!? A quiet failure too, the 'scope would just suddenly shutdown, or just fail to power up when needed.? No uncontrolled "Fire and Brimstone" events.? Plus, the bad ones were difficult to spot, unless they sported a small silver "blob" somewhere on their body, but they we found would often fall off during de-casing the instrument.

The quickest way to find them was brutal.? Pull the collapsed PSU rail current limit sense transistor and wait....? Sometimes it would take another hour, other times a few seconds.? I used to put the s'cope on a turntable standing on it's rear with the cover off, so it could be rotated when the smoke came, to find the culprit.? (With the intensity turned down, and fully de-focused, in case when a cap' failed, that could result in a static high intensity beam.)

Power down, remove, clean up, install new part, taking great care to fit the right way round!? And re-test.? One instrument went through that three times that I know off.? Most, were just single event failures.

Of course, a full performance / calibration check was performed before returning the unit to the customer.

In Tek's defence, those parts were the multi coloured bead types.? Some makes were not exactly obvious which lead was the +ve from the colours and layout of the markings used..

I still wonder if any survived and "re-polarised" themselves (If Tant' cap's can even do that) and have had a long working life.? I have a 465 and 485, both riddled with the things, both still work well.

Regards to All.

Dave 'KBV



Re: HP 8341B 1992 firmware version

 

Saevar, Dmitrij,
One more question - I'm a little afraid of doing firmware update, because I have just found this topic:
/g/HP-Agilent-Keysight-equipment/message/137236
I'm afraid that after firmware upgrade I can break the unit without even having possibility of returning to old firmware...
Do you to know why?
?
?
?
?
Regards,
Wojciech


Re: Tantalum Capacitors

 

Hi! Mostly the 1100 series, some 1400 and I had a 1200 come around. I still have a few examples in my stash. I lived near Goddard SFC and attended the sales there in Bldg 16W, got lots of Microdyne back in the day, Also had lots of the competitors stuff as well. Have cleaned out most of it (some Microdyne of mine went to Fair Radio, he didnt understand it..) and recently sent 5500 pounds to e-scrap- some diversity combiners in there. Hated those 47u at 35 volt caps (dipped) always bad! You must have worked on the newer stuff after they moved from the DC area., No surface mount in my stuff! Some of the 1100 were used by NSA, from DoD sales, had a VLF tuner, I guess for subcarrier work. Documentation was rare..
Regards,
Jeff

In a message dated 11/28/2024 3:19:30 AM Eastern Standard Time, terrell.michael.a@... writes:
?
What series of Microdye radios did you service? I worked on many of them at their factory in Ocala. We still produced some 1100 series, 1200, 1400, 700/1620, and the RCB2000 during my time there. They had also built their many 1100 series satellite receivers at that plant. We had some VXI boards for custom Telemetry products, but they were handled by the Engineering techs. We were using mostly SMD or molded tubular Tantalum during the 1997 to 2001 period. I don't recall any dipped tantalum, so the older designs must have ad the borads spn to change to the tubular style.


Re: VNA Resonance Methodology

 

Wow! This thread seems to have taken on a life of it's own. Who'd have thought such a simple tank circuit could generate so much interest?
I'm just finishing my lunch break right now and just wanted to say I *will* read all the responses later tonight after I get home and endeavour to answer any points made before I turn in around midnight GMT.
Thanks, all!


Re: VNA Resonance Methodology

 

¿ªÔÆÌåÓý

Sorry : ?Q =Fo/BW?


Ing. Patricio A. Greco
Taller Aeron¨¢utico de Reparaci¨®n 1B-349
Organizaci¨®n de Mantenimiento?Aeron¨¢utico de la Defensa OMAD-001
Laboratorio de Calibraci¨®n ISO 17025?AREA: RF/MW?
Gral. Mart¨ªn Rodr¨ªguez 2159
San Miguel (1663)
Buenos Aires
T: +5411-4455-2557
F: +5411-4032-0072




On 28 Nov 2024, at 10:41, Patricio A. Greco via <patricio_greco@...> wrote:

Hi: I¡¯m following this topic and its really interesting. If the VNA port is properly calibrated you can connect any dipole on it and measure impedance. The instrument must to be calibrated at the reference plane this can include a cable for example. In general the resonance frequency Fo happens when the reactive part of impedance nulls. At this frequency you have a resistance Rp. The problem to compute Q in this case is that you need to know L of resonant circuit this is proportional to energy stored on reactive components¡­ Q is a ratio between the lost energy on each cycle and the energy storage on reactive components. You should to disconnect C from circuit and measure L but you never can measure the value of L because you have a parasitic Co ¡­ capacitance between turns¡­ so the better way to compute Q is to use the bandwidth the you can measure with VNA. If you plot the modulus of Z and take the bandwidth al 70,7% of the peak Q= BW/Fo.?





There are several problems that can happen on measurement, if you pretend to measure high Q circuit as the VNA has a reference of 50 Ohm values of R > 600 ohm will be inaccurately measured it propagates errors to results as Fo / Q . The same problem will happen with the same components if you switch to serial configuration where the series equivalent resistor will be very low. Also don?y forget our parasitic capacitance Co it will shift the resonance frequency between configurations. The calibration accuracy is very important also , take care to have very good standards , specially short for series and open for parallel configurations you will work close to these extremes with reasonable quality components. The connections between the VNA port and components under test would be made with care because they also are included on measurement.?
In this case for higher Q values the best is to use a transformer coupling with other coil would be a good idea but it introduces a new L? on circuit. ?On coupled inductors you have the self inductance of each one and the mutual inductance. But all depends on the accuracy that you need. ?In some cases a transformer would be used or a balun and the port would be calibrated with them included.?
Finally its possible to measure Co if you have a previously measured capacitors. Co depends strongly on frequency , it depends on dielectric properties of winding form¡­ and all you can imagine factors. for air inductors it would be more stable. So the method to measure is very old and used with Q meters. First you need to get resonance at desired measurement frequency and then vary the capacitor a known value and get a new resonant frequency. The idea is to get values around the measurement point. You will have values?

(F1,C1) , (F2,C2), (F3,C3)?

Then Omega= 2 Pi f and you can plot: ?1/Omega^2 = L. C, as you van see on the plot a made by hand ( sorry for that ) the points represent the measured values ?if you get a few points the green line can be drown as the line that pass by the points on the mean this is the best you can do. If you get more points it will define a curve ?and his pendent is L ( that also varies with frequency) the green line is the tangent to this curve at the desired frequency. C scale are really shifted by Co then it don't cross the ?origin when you project it, so you can determine Co as you can see on plot.?

?
<Graph.png>


I really hope it would be useful.

Regards, Patricio.?


Ing. Patricio A. Greco
Laboratorio de Calibraci¨®n ISO 17025?AREA: RF/MW?
Gral. Mart¨ªn Rodr¨ªguez 2159
San Miguel (1663)
Buenos Aires
T: +5411-4455-2557
F: +5411-4032-0072




On 28 Nov 2024, at 06:59, Dave_G0WBX via??<g8kbvdave@...> wrote:

If you reconfigure the LC circuit, as a series resonant element, I suspect you'll see "Resonance" as a point at/near the SmithChart centre point, where the L and C almost cancel themselves, leaving the resistor for the VNA to "see".? Any losses (resistance in the inductor, or losses in the capacitor) should show as a less than perfect 50r match at resonance.

Try it and see perhaps?

73.

Dave 'KBV





Re: VNA Resonance Methodology

 

¿ªÔÆÌåÓý

Hi: I¡¯m following this topic and its really interesting. If the VNA port is properly calibrated you can connect any dipole on it and measure impedance. The instrument must to be calibrated at the reference plane this can include a cable for example. In general the resonance frequency Fo happens when the reactive part of impedance nulls. At this frequency you have a resistance Rp. The problem to compute Q in this case is that you need to know L of resonant circuit this is proportional to energy stored on reactive components¡­ Q is a ratio between the lost energy on each cycle and the energy storage on reactive components. You should to disconnect C from circuit and measure L but you never can measure the value of L because you have a parasitic Co ¡­ capacitance between turns¡­ so the better way to compute Q is to use the bandwidth the you can measure with VNA. If you plot the modulus of Z and take the bandwidth al 70,7% of the peak Q= BW/Fo.?





There are several problems that can happen on measurement, if you pretend to measure high Q circuit as the VNA has a reference of 50 Ohm values of R > 600 ohm will be inaccurately measured it propagates errors to results as Fo / Q . The same problem will happen with the same components if you switch to serial configuration where the series equivalent resistor will be very low. Also don?y forget our parasitic capacitance Co it will shift the resonance frequency between configurations. The calibration accuracy is very important also , take care to have very good standards , specially short for series and open for parallel configurations you will work close to these extremes with reasonable quality components. The connections between the VNA port and components under test would be made with care because they also are included on measurement.?
In this case for higher Q values the best is to use a transformer coupling with other coil would be a good idea but it introduces a new L? on circuit. ?On coupled inductors you have the self inductance of each one and the mutual inductance. But all depends on the accuracy that you need. ?In some cases a transformer would be used or a balun and the port would be calibrated with them included.?
Finally its possible to measure Co if you have a previously measured capacitors. Co depends strongly on frequency , it depends on dielectric properties of winding form¡­ and all you can imagine factors. for air inductors it would be more stable. So the method to measure is very old and used with Q meters. First you need to get resonance at desired measurement frequency and then vary the capacitor a known value and get a new resonant frequency. The idea is to get values around the measurement point. You will have values?

(F1,C1) , (F2,C2), (F3,C3)?

Then Omega= 2 Pi f and you can plot: ?1/Omega^2 = L. C, as you van see on the plot a made by hand ( sorry for that ) the points represent the measured values ?if you get a few points the green line can be drown as the line that pass by the points on the mean this is the best you can do. If you get more points it will define a curve ?and his pendent is L ( that also varies with frequency) the green line is the tangent to this curve at the desired frequency. C scale are really shifted by Co then it don't cross the ?origin when you project it, so you can determine Co as you can see on plot.?

?


I really hope it would be useful.

Regards, Patricio.?


Ing. Patricio A. Greco
Laboratorio de Calibraci¨®n ISO 17025?AREA: RF/MW?
Gral. Mart¨ªn Rodr¨ªguez 2159
San Miguel (1663)
Buenos Aires
T: +5411-4455-2557
F: +5411-4032-0072




On 28 Nov 2024, at 06:59, Dave_G0WBX via <g8kbvdave@...> wrote:

If you reconfigure the LC circuit, as a series resonant element, I suspect you'll see "Resonance" as a point at/near the SmithChart centre point, where the L and C almost cancel themselves, leaving the resistor for the VNA to "see".? Any losses (resistance in the inductor, or losses in the capacitor) should show as a less than perfect 50r match at resonance.

Try it and see perhaps?

73.

Dave 'KBV




Re: Tantalum Capacitors

 

Weren't some of these only identified by the lead length of the positive side?

On Thu, Nov 28, 2024 at 6:05?AM Dave_G0WBX via <g8kbvdave=[email protected]> wrote:

Re:-

"Some tantalum capacitors needed a small resistor of a few ohms in series with the supply voltage to limit the dV/dt and inrush current as well."


Oh Yes indeed!? In truth, I suspect all "Tantalum" cap's have a surge current limit, that if exceeded will do them damage...

In the immediate past full time day job, I ended up having to replace several SMD type 68uF/50V parts (similar to these: ) that were used to decouple an incoming +20V high current supply, that itself was switched by a relay contact.? The PSU was rated at several 100W on that rail.

I quite soon (with a bit of online research) discovered they don't tolerate surge currents that well (if at all) but could not convince our product designers of that fact, even by sending them extracts, and complete data sheets from the manufacturer they used.

(The relay contact would also pit and fail after some time too.? Another "schoolboy mistake" they made, but again not interested in mitigating.? In later versions of that product, the PSU was commanded On/Off, rather than use a relay on it's output.? It was a custom multi-rail type by then, so I guess someone else with more clout than a wholly owned subsidiary doing support and repairs could wield.)

I (like others on this list) fitted electrolytic parts instead, if they fitted inside the module (and other parts of the module, such as nearby components or the board itself were not badly damaged.)? Else, they were fitted to the outside of the case.

The data sheet from maker used (Vishay I think in that case, but I cannot be sure of that) also indicated that the larger SMD Tantalum parts, needed "annealing" after soldering to a board, to reduce/remove internal stresses built up during the SMD soldering phase, that could cause premature failure.? Something else our "engineering" types did not want to know, and/or failed to acknowledge.

In a past (much earlier) work life, I had first hand experience while working for Tek in the UK, of the great "Tantalum fitted the wrong way round issue" in such instruments as the venerable Tek 465 'scope.? Oddly, they'd often last long enough to just get past the warranty period!? A quiet failure too, the 'scope would just suddenly shutdown, or just fail to power up when needed.? No uncontrolled "Fire and Brimstone" events.? Plus, the bad ones were difficult to spot, unless they sported a small silver "blob" somewhere on their body, but they we found would often fall off during de-casing the instrument.

The quickest way to find them was brutal.? Pull the collapsed PSU rail current limit sense transistor and wait....? Sometimes it would take another hour, other times a few seconds.? I used to put the s'cope on a turntable standing on it's rear with the cover off, so it could be rotated when the smoke came, to find the culprit.? (With the intensity turned down, and fully de-focused, in case when a cap' failed, that could result in a static high intensity beam.)

Power down, remove, clean up, install new part, taking great care to fit the right way round!? And re-test.? One instrument went through that three times that I know off.? Most, were just single event failures.

Of course, a full performance / calibration check was performed before returning the unit to the customer.

In Tek's defence, those parts were the multi coloured bead types.? Some makes were not exactly obvious which lead was the +ve from the colours and layout of the markings used..

I still wonder if any survived and "re-polarised" themselves (If Tant' cap's can even do that) and have had a long working life.? I have a 465 and 485, both riddled with the things, both still work well.

Regards to All.

Dave 'KBV



Re: Tantalum Capacitors

 

¿ªÔÆÌåÓý

Re:-

"Some tantalum capacitors needed a small resistor of a few ohms in series with the supply voltage to limit the dV/dt and inrush current as well."


Oh Yes indeed!? In truth, I suspect all "Tantalum" cap's have a surge current limit, that if exceeded will do them damage...

In the immediate past full time day job, I ended up having to replace several SMD type 68uF/50V parts (similar to these: ) that were used to decouple an incoming +20V high current supply, that itself was switched by a relay contact.? The PSU was rated at several 100W on that rail.

I quite soon (with a bit of online research) discovered they don't tolerate surge currents that well (if at all) but could not convince our product designers of that fact, even by sending them extracts, and complete data sheets from the manufacturer they used.

(The relay contact would also pit and fail after some time too.? Another "schoolboy mistake" they made, but again not interested in mitigating.? In later versions of that product, the PSU was commanded On/Off, rather than use a relay on it's output.? It was a custom multi-rail type by then, so I guess someone else with more clout than a wholly owned subsidiary doing support and repairs could wield.)

I (like others on this list) fitted electrolytic parts instead, if they fitted inside the module (and other parts of the module, such as nearby components or the board itself were not badly damaged.)? Else, they were fitted to the outside of the case.

The data sheet from maker used (Vishay I think in that case, but I cannot be sure of that) also indicated that the larger SMD Tantalum parts, needed "annealing" after soldering to a board, to reduce/remove internal stresses built up during the SMD soldering phase, that could cause premature failure.? Something else our "engineering" types did not want to know, and/or failed to acknowledge.

In a past (much earlier) work life, I had first hand experience while working for Tek in the UK, of the great "Tantalum fitted the wrong way round issue" in such instruments as the venerable Tek 465 'scope.? Oddly, they'd often last long enough to just get past the warranty period!? A quiet failure too, the 'scope would just suddenly shutdown, or just fail to power up when needed.? No uncontrolled "Fire and Brimstone" events.? Plus, the bad ones were difficult to spot, unless they sported a small silver "blob" somewhere on their body, but they we found would often fall off during de-casing the instrument.

The quickest way to find them was brutal.? Pull the collapsed PSU rail current limit sense transistor and wait....? Sometimes it would take another hour, other times a few seconds.? I used to put the s'cope on a turntable standing on it's rear with the cover off, so it could be rotated when the smoke came, to find the culprit.? (With the intensity turned down, and fully de-focused, in case when a cap' failed, that could result in a static high intensity beam.)

Power down, remove, clean up, install new part, taking great care to fit the right way round!? And re-test.? One instrument went through that three times that I know off.? Most, were just single event failures.

Of course, a full performance / calibration check was performed before returning the unit to the customer.

In Tek's defence, those parts were the multi coloured bead types.? Some makes were not exactly obvious which lead was the +ve from the colours and layout of the markings used..

I still wonder if any survived and "re-polarised" themselves (If Tant' cap's can even do that) and have had a long working life.? I have a 465 and 485, both riddled with the things, both still work well.

Regards to All.

Dave 'KBV



Re: VNA Resonance Methodology

 

¿ªÔÆÌåÓý

If you reconfigure the LC circuit, as a series resonant element, I suspect you'll see "Resonance" as a point at/near the SmithChart centre point, where the L and C almost cancel themselves, leaving the resistor for the VNA to "see".? Any losses (resistance in the inductor, or losses in the capacitor) should show as a less than perfect 50r match at resonance.

Try it and see perhaps?

73.

Dave 'KBV



Re: Tantalum Capacitors

 

What series of Microdye radios did you service? I worked on many of them at their factory in Ocala. We still produced some 1100 series, 1200, 1400, 700/1620, and the RCB2000 during my time there. They had also built their many 1100 series satellite receivers at that plant. We had some VXI boards for custom Telemetry products, but they were handled by the Engineering techs. We were using mostly SMD or molded tubular Tantalum during the 1997 to 2001 period. I don't recall any dipped tantalum, so the older designs must have ad the borads spn to change to the tubular style.

On Wed, Nov 27, 2024 at 11:08?PM Jeff Kruth via <kmec=[email protected]> wrote:
So, on the subject of those dipped "orange drop" tants: they suck.? They go bad with age seemingly, because I am told, the seal is not made to last and they dry out and short. I have seen literally hundreds of these in Watkins Johnson & Microdyne radios, EIP counters, HP gear (not used often) go bad, sometimes burning and marring the circuit board. They are my first suspect when looking for shorted power supply lines.
Now, on the other hand, hermetically sealed mil type of tants seem to last forever.
I have seen stashes of the dipped type go bad, just sitting on the shelf. I will not use them and when I get some in a box of parts, I get rid of them.
True experiences, not conjecture. They have LONG outlived their economic lifetime in our gear.


Re: HP 8341B 1992 firmware version

 

Hi Saevar, Dmitrij,
Thank you very much for all the information. I will try these then.
Thanks, Wojciech


Re: Tantalum Capacitors

 

They have smaller ESR (also should be able to reach higher frequencies). I replace them with low ESR high temp aluminum ones (usually 50V). Additionally one can add the 100nF SMD between the legs.
?
In computers they are also the pain. Look to Adrian basement channel on youtube. He repaired some computer where the caps were used on the bus and was explaining, that if one fails usually the other goes bad at the next turn on after the repair.


Re: VNA Resonance Methodology

 

Jinxie,

Bravo for the fine notes and topic. Happy to send you links or pix if you are interested.

As a kid I wound Tesla coils since 1956 (!) of increasing sizes.

By 1970s..1980s got classic Boonton 260A Q meter (boatanchor)
and at Silicon Valley ham fleas many Boonton/Measurements GDO.

The Tesla coils are always air wound solenoids,
Primary and secondary should be tuned to same freq, normally 20kHz..500 kHz.
See our old friend Gred LEYH at LOD.ORG

Classic GDO and Q meter were VERY handy to design and tune Teslas coils.
Boonton supplied calibrated stable L and Q standards in metal cans and bannana plug to calibrate.

We can connect, if you PM email

Amicalment

Jon


Re: Tantalum Capacitors

 

Forgot to mention - one thing I've noticed is that much more modern non-hermetic Ta caps like encountered in surface-mount on things like PCs and laptops, don't seem to be much trouble. I'd expect that more modern components of all types should benefit from technical advancements.
?
Ed


Re: Tantalum Capacitors

 

So, on the subject of those dipped "orange drop" tants: they suck.? They go bad with age seemingly, because I am told, the seal is not made to last and they dry out and short. I have seen literally hundreds of these in Watkins Johnson & Microdyne radios, EIP counters, HP gear (not used often) go bad, sometimes burning and marring the circuit board. They are my first suspect when looking for shorted power supply lines.
Now, on the other hand, hermetically sealed mil type of tants seem to last forever.
I have seen stashes of the dipped type go bad, just sitting on the shelf. I will not use them and when I get some in a box of parts, I get rid of them.
True experiences, not conjecture. They have LONG outlived their economic lifetime in our gear.


Re: Tantalum Capacitors

 

I think you'll find that your stock of non-hermetic (like dipped) Ta caps are less reliable than expected, due to environmental issues like humidity after many years, even if never used before. The operating voltage versus specified is a big factor as we've seen over the years, but there's more to it than that. I have quite a few old Ta caps in dipped and hermetic (like Sprague 105D style) forms, and still prefer them over any vintage of Al parts up to a practical limit around 300 uF or so. The hermetic ones are the most reliable, especially with age (but not immune to problems).
?
The old dipped ones should still be acceptable, but maybe de-rate them voltage-wise even more than usual for best results. I think there are quality vs brand issues too, but that's hard to figure out. More than once I've thought I figured out which ones to use and which to avoid, only to be proven wrong later. The ones I distrust the most are the color-coded "rainbow" types often seen in Tek equipment from the 1970s-1980s. But, I've been wrong on that enough times too.
?
Ed


Re: Tantalum Capacitors

 

Some tantalum capacitors needed a small resistor of a few ohms in series with the supply voltage to limit the dV/dt and inrush current as well.

Hugh Gilbert


On Wed, Nov 27, 2024 at 8:57?PM Brian via <brianclarke01=[email protected]> wrote:

Hello Gary,

Tantalum capacitors¡¯ working Voltage rating is for marketing purposes only. The Arrhenius equation regarding time to failure applies. As you approach the rated Voltage, the time to failure gets shorter and shorter. When I replace tantalum capacitors, I use ones rated (marketed) with double my expected operating Voltage.

When tantalum capacitors first became available, printed wiring board designers took advantage of the smaller size of tantalum capacitors and crammed them onto the board.? When I repair a board, if there¡¯s enough room, I generally replace tantalum capacitors with good-quality low-ESR electrolytic capacitors.

73 de Brian, VK2GCE

?

From: [email protected] [mailto:[email protected]] On Behalf Of Gary Appel
Sent: Thursday, 28 November 2024 12:34 PM
To: [email protected]
Subject: [HP-Agilent-Keysight-equipment] Tantalum Capacitors

?

I'm sure we've all repaired some equipment where a tantalum capacitor has shorted.?

?

I lived for 30 years in San Jose, and collected lots of parts, including a lifelong supply of teardrop tantalum capacitors of various values and voltages. I have used these in projects over the years with no trouble. But over the past few years they seem to fail immediately. Today I had to replace a tantalum capacitor in an HP 5328A counter, and the replacement immediately failed. I placed another one on a power supply and ran the voltage up to 15 volts for a 20 volt capacitor. The supply briefly went in to current? limiting multiple times before the capacitor failed completely.

?

Do tantalum capacitors degrade with time with no voltage supplied? Or do I just have a bunch of poor quality parts?

?

Any information would be appreciated - although regardless, I think it may be time to toss my collection of tantalum capacitors.

?

Gary Appel


Re: Tantalum Capacitors

 

¿ªÔÆÌåÓý

Hello Gary,

Tantalum capacitors¡¯ working Voltage rating is for marketing purposes only. The Arrhenius equation regarding time to failure applies. As you approach the rated Voltage, the time to failure gets shorter and shorter. When I replace tantalum capacitors, I use ones rated (marketed) with double my expected operating Voltage.

When tantalum capacitors first became available, printed wiring board designers took advantage of the smaller size of tantalum capacitors and crammed them onto the board. ?When I repair a board, if there¡¯s enough room, I generally replace tantalum capacitors with good-quality low-ESR electrolytic capacitors.

73 de Brian, VK2GCE

?

From: [email protected] [mailto:[email protected]] On Behalf Of Gary Appel
Sent: Thursday, 28 November 2024 12:34 PM
To: [email protected]
Subject: [HP-Agilent-Keysight-equipment] Tantalum Capacitors

?

I'm sure we've all repaired some equipment where a tantalum capacitor has shorted.?

?

I lived for 30 years in San Jose, and collected lots of parts, including a lifelong supply of teardrop tantalum capacitors of various values and voltages. I have used these in projects over the years with no trouble. But over the past few years they seem to fail immediately. Today I had to replace a tantalum capacitor in an HP 5328A counter, and the replacement immediately failed. I placed another one on a power supply and ran the voltage up to 15 volts for a 20 volt capacitor. The supply briefly went in to current? limiting multiple times before the capacitor failed completely.

?

Do tantalum capacitors degrade with time with no voltage supplied? Or do I just have a bunch of poor quality parts?

?

Any information would be appreciated - although regardless, I think it may be time to toss my collection of tantalum capacitors.

?

Gary Appel