Date

Request for HP 1740A Oscilloscope Manual

David Jarman
 

Hi All!

I have recently acquired an HP 1740A dual-beam oscilloscope - but
alas without a User Manual.

I would appreciate help in acquiring a manual from this expert Yahoo
group.

Best Regards

David


Re: HP8656A

John Miles
 

开云体育

Which oscillator?
?
-- jm

-----Original Message-----
From: Richard W. Murray [mailto:inertial@...]
Sent: Tuesday, February 17, 2004 8:48 PM
To: hp_agilent_equipment@...
Subject: Re: [hp_agilent_equipment] HP8656A

I found similar problems with my 8656A.? I replaced all electrolytic caps.? I also replaced the osc. I believe it's a FET,? try Sphere in B.C. they had some.? I still have one extra.? It's not as clean as my 8647A but 100% better.
?
Regards
?
Richard Murray


Re: HP8656A

 

开云体育

I found similar problems with my 8656A.? I replaced all electrolytic caps.? I also replaced the osc. I believe it's a FET,? try Sphere in B.C. they had some.? I still have one extra.? It's not as clean as my 8647A but 100% better.
?
Regards
?
Richard Murray


Re: HP8656A

John Miles
 

They all do that. The 8656A has a lot of close-in phase noise. Not clean
enough for any SSB work that requires an extremely stable reference.

-- john KE5FX

-----Original Message-----
From: halkinley [mailto:halkinley@...]
Sent: Monday, February 16, 2004 10:09 AM
To: hp_agilent_equipment@...
Subject: [hp_agilent_equipment] HP8656A


I have a HP8656A signal generator. Works fine for FM and AM.
However, when using it to test a SSB receiver there is a
pronounced "warble" in the tone and it is serious enough to affect
the measurements. Any clue as to where to look for the trouble? A
friend of mine bought one at the same time and place as I did (used
equipment dealer) and his does the same thing. Any ideas or
suggestions on how to repair it? Thanks,
Hal Kinley
WA4GIB




Yahoo! Groups Links






HP8656A

 

I have a HP8656A signal generator. Works fine for FM and AM.
However, when using it to test a SSB receiver there is a
pronounced "warble" in the tone and it is serious enough to affect
the measurements. Any clue as to where to look for the trouble? A
friend of mine bought one at the same time and place as I did (used
equipment dealer) and his does the same thing. Any ideas or
suggestions on how to repair it? Thanks,
Hal Kinley
WA4GIB


Re: Looking for... (Benchlink)

 

Hi Dave,
Thank you very much for your help.
I am going to download the free trial.
May be that?s enough for my job.
Regards,

--- In hp_agilent_equipment@..., Dave Haupt
<emailw8nf@y...> wrote:
Carlos,

I just went to the Agilent website. I was shocked to
see that Benchlink for spectrum analyzers appears to
sell for $310!!!

Agilent did not write this software themselves, but
sourced it from a third party. Agilent could not
allow unlimited downloads legally.

However, I see that they do appear to have a "free
trial" for four weeks of the software. Might be worth
trying that.

Go to their website - www.agilent.com - and enter
"E4444A" in the search box. You'll get several links,
including one to the free trial download.

As I recall, the software works with the 8590 and 8560
series analyzers. Benchlink runs on your PC, and you
have to have a physical way to connect the PC and
spectrum analyzer. For the 8560 series, only an HPIB
card can do this. For the 8590 series, it can be HPIB
or serial, depending on which options you have
installed in the analyzer.

Hope this helps!

73,

Dave W8NF


Date: Thu, 12 Feb 2004 15:45:36 -0000
From: "fox342002" <fox342002@h...>
Subject: RE: looking for...

Hi,
I would like very much to transfer to my PC data
from my Spectrum
Analyzer.
Someone told me I need this software to do the job:
"E4444A BenchLink
Spectrum Analyzer Connectivity Software".
Would somebody point me to a direction in order to
download it?
Thank you all and
Best Regards,
Carlos

__________________________________
Do you Yahoo!?
Yahoo! Finance: Get your refund fast by filing online.


Re: Looking for... (Benchlink)

Dave Haupt
 

Carlos,

I just went to the Agilent website. I was shocked to
see that Benchlink for spectrum analyzers appears to
sell for $310!!!

Agilent did not write this software themselves, but
sourced it from a third party. Agilent could not
allow unlimited downloads legally.

However, I see that they do appear to have a "free
trial" for four weeks of the software. Might be worth
trying that.

Go to their website - www.agilent.com - and enter
"E4444A" in the search box. You'll get several links,
including one to the free trial download.

As I recall, the software works with the 8590 and 8560
series analyzers. Benchlink runs on your PC, and you
have to have a physical way to connect the PC and
spectrum analyzer. For the 8560 series, only an HPIB
card can do this. For the 8590 series, it can be HPIB
or serial, depending on which options you have
installed in the analyzer.

Hope this helps!

73,

Dave W8NF


Date: Thu, 12 Feb 2004 15:45:36 -0000
From: "fox342002" <fox342002@...>
Subject: RE: looking for...

Hi,
I would like very much to transfer to my PC data
from my Spectrum
Analyzer.
Someone told me I need this software to do the job:
"E4444A BenchLink
Spectrum Analyzer Connectivity Software".
Would somebody point me to a direction in order to
download it?
Thank you all and
Best Regards,
Carlos

__________________________________
Do you Yahoo!?
Yahoo! Finance: Get your refund fast by filing online.


Re: looking for...

 

Hi,
I would like very much to transfer to my PC data from my Spectrum
Analyzer.
Someone told me I need this software to do the job: "E4444A BenchLink
Spectrum Analyzer Connectivity Software".
Would somebody point me to a direction in order to download it?
Thank you all and
Best Regards,
Carlos


Re: Looking for obscure HP 1884- xxxx series parts

 

--- In hp_agilent_equipment@..., "wshawlee2"
<walter2@s...> wrote:
Hi,
does anybody have some spare TO-3 Hp 1884-0019 parts?
they are SCRs or Triacs used in power supply pre-regulators, RCA was
the manufacturer. I need either the real part number or
some HP parts if avaiable. Not listed anywher in my bench briefs, or
on line archives, so any help appreciated.

many thanks,
walter

sphere research corporation
Hi Walter,

its a 2N3669.

HP 1884-0019:

VRRM 200V
VDRM 600V
IT (RMS) 12.5A
ITSM 200A
PG 0.5W
PGM 40W
VT (MIN)200V
IGT MAX 40.0m
VGT MAX 1.5V
VTM MAX 1.8V
Outline Drawing 2 (...)
JEDEC NO 2N3669
JEDEC PKG TYPE TO-3

From "HP Semiconductor Identification Table and Cross Reference"

October 1975

Jorgen


Re: H-P 184A/Fred

Fred Olsen
 

OK, Richard, I'll see what I can do. I'll need a couple of days to dig these up out of (shudder!) "The Storage". I don't maintain the scope in-cal any more and the manuals are in the dead file. Did you say that you had an 1809 or an 1809A? Send me the three S/Ns, privately if you wish, and I'll check S/N applicability when I find the books.

I'm not unwilling to copy the books for you but it's a matter of time. The three together must be at least an inch thick, IIRC. And they're glue bound and I know would fall apart if forced hard enough for decent copies. We'll see.

In any event, perhaps we should take this thread private. Don't know if anyone else would care much about the gory details.

So how's the weather in Modesto?

Fred
--
<><
--
Outgoing checked by Norton AV


Re: H-P 184A/Fred

free2beme953572002
 

--- In hp_agilent_equipment@..., Fred Olsen
<fwolsen@e...> wrote:
I have a functional 184A with an 1809A and 1825A, and the manuals.
They're a bit much to copy outright but if I might be of some help
please ask.

Fred
--
<><
--
Outgoing checked by Norton AV
Hi Fred,
OK,how about the HV section ?
What has happened, is similar to "blooming" in a TV set.
I haven't removed the side panels, yet. Focus,etc, has no effect.
But, the problem may be in the sweep section.
The scope looks like in fair condition. Hard telling what this scope
went through.One of the wrapcord foot is broken.
Some knobs are hard to turn.
Other than that, looks like a nice scope.
For now, I'll suspect the HV section.
Now, got to put together my 2 Tek 465M's. Atleast,my Tek 7704A
(newest)works.Can use this one to troubleshoot the rest.
Thanks Fred.
If you like, you can send the info to blackbag@....
BTW, I'm Richard.Now you know.


Re: H-P 184A

Fred Olsen
 

Robert Middleton wrote:
Is there a possibility
that you might know where I can locate some
Hewlett Packard oscilloscopes?
do you and or your friends happen to have any old vacuum
tubes for sale,
Robert, it looks like we both got snagged by the 'reply to list' setting. No, I neither have nor know of availability of any of the models you listed. My collection is primarily Tek. Best of luck.
I do not wish to sell any of my tube stock at this time.

I don't at all mind being asked but my reply was directed to "free2beme953572002" (man I just LOVE trying to 'talk' to someone behind one of those nicknames) who asked for some 184A information. I take the messages as email and forgot that this list is set to send everything back to everybody. Perhaps Mr. Moderator (is that Tom Leedy?) would consider setting it the other way, as it is on the Tek list? Most folks are smart enough to figure out whether a reply should be public or private.

End of two-cent rant,
Fred
--
<><
--
Outgoing checked by Norton AV


Re: H-P 184A

Robert Middleton
 

开云体育

?
----- Original Message -----
Sent: Sunday, February 01, 2004 11:38 PM
Subject: Re: [hp_agilent_equipment] H-P 184A

Hello Fred.
?
This is Robert. Thank you for your e-mail. Is there a possibility that you might know where I can locate some of the older tube type Hewlett Packard oscilloscopes? Enclosed is a list of what I am looking for.
?
Also, if you have any friends who might have any of these or perhaps they can let me know where I can locate some of these older HP tube type oscilloscopes, please have them contact me at; romhifi@...
?
Thanks for your time and you and yours have a great day.
?
Respectfully, Robert
?
p.s. Below is a partial list of the older tube type Hewlett Packard oscilloscopes I am in search of, thank you.
?
?
OS-121A/USM-140
0S-82A/USM-105
0S-121C/USM-140
?
There are a few others too that I am looking for however I don't have the list in front of me. I appreciate any help that you and or your friends can come up with. Thanks again and take care.
?
By the way, do you and or your friends happen to have any old vacuum tubes for sale, used and untested as well as New tubes are always welcome thank you.
?
?
----- Original Message -----
From: Fred Olsen
Sent: Sunday, February 01, 2004 11:24 PM
Subject: Re: [hp_agilent_equipment] H-P 184A

I have a functional 184A with an 1809A and 1825A, and the manuals.
They're a bit much to copy outright but if I might be of some help
please ask.

Fred
--
<><
--
Outgoing checked by Norton AV




Yahoo! Groups Links



Yahoo! Groups Links


Re: H-P 184A

Robert Middleton
 

开云体育

Hello Fred.
?
This is Robert. Thank you for your e-mail. Is there a possibility that you might know where I can locate some of the older tube type Hewlett Packard oscilloscopes? Enclosed is a list of what I am looking for.
?
Also, if you have any friends who might have any of these or perhaps they can let me know where I can locate some of these older HP tube type oscilloscopes, please have them contact me at; romhifi@...
?
Thanks for your time and you and yours have a great day.
?
Respectfully, Robert
?
p.s. Below is a partial list of the older tube type Hewlett Packard oscilloscopes I am in search of, thank you.
?
?
OS-121A/USM-140
0S-82A/USM-105
0S-121C/USM-140
?
There are a fewothers too that I am looking for however I don't have the list in front of me. I appreciate any help that you and or your friends can come up with. Thanks again and take care.
?
?

----- Original Message -----
From: Fred Olsen
Sent: Sunday, February 01, 2004 11:24 PM
Subject: Re: [hp_agilent_equipment] H-P 184A

I have a functional 184A with an 1809A and 1825A, and the manuals.
They're a bit much to copy outright but if I might be of some help
please ask.

Fred
--
<><
--
Outgoing checked by Norton AV




Yahoo! Groups Links


Re: H-P 184A

Fred Olsen
 

I have a functional 184A with an 1809A and 1825A, and the manuals. They're a bit much to copy outright but if I might be of some help please ask.

Fred
--
<><
--
Outgoing checked by Norton AV


Re: HP-184A/Service Manual

free2beme953572002
 

Hi All,
Looks like it's "request a service manual" time.
The mil site had nothing.
So, I request it.
thanks.


H-P 184A

free2beme953572002
 

Just bought an HP-184A scope today at the monthly Livermore
Electronics Flea Market.
Plus, a Tektronix 7704A mainframe scope....$ 15.00 !Checked it at
home.The readout does work.In decent,good condition.A keeper.
Used my 7000 series plug-ins.
OOOPs ! Am I allowed to say "Tektronix"?
Has 2 plug-ins; a 1809 4 channel, 100 MHZ vertical. And an 1825A
timebase and H amp.The mainframe is a storage type.
Couldn't pass it up for $ 20.00.
Now, for the interesting part:No trace, but a glowing screen.
Beamfinder is useless.No spot. Just the screen glowing.
Tried BAMA for the service manual.Not in there.
Next, will try the mil site.
Stand by for a service manual request.
Just to let you all know what can be had, at the right price(s).


Re: Digest Number 58

 

Walter,

I looked up your HP part number, 1884-0019, in my copy of the FedLog (Federal Logistics) database.

This is one of the first times it hasn't shown ANY equivalent part numbers and other manufacturers.

But it did have some technical descriptive data, which I'll paste below, in case it might be helpful.

Good luck!

Tom Gootee



-----------------------------------

Characteristics Data Response for NSN 5961-01-219-7784
Item Name: SEMICONDUCTOR DEVICE,THYRISTOR

MRC Requirement Statement Clear Text Reply
--------------------------------------------------------------------
NAME ITEM NAME SEMICONDUCTOR DEVICE,THYRISTOR
ABBH INCLOSURE MATERIAL METAL
ABHP OVERALL LENGTH 1.573 INCHES MAXIMUM
ABKW OVERALL HEIGHT 0.450 INCHES MAXIMUM
ABMK OVERALL WIDTH 1.050 INCHES MAXIMUM
AKPV MOUNTING FACILITY QUANTITY 2
ALAS INTERNAL CONFIGURATION JUNCTION CONTACT
ALAZ JOINT ELECTRONIC DEVICE TO-3
ENGINEERING
COUNCIL/JEDEC/CASE OUTLINE
DESIGNATION
ASCQ INTERNAL JUNCTION PNPN
CONFIGURATION
AXGY MOUNTING METHOD UNTHREADED HOLE
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
CTMZ SEMICONDUCTOR MATERIAL SILICON
CTQN VOLTAGE RATING IN VOLTS PER 200.0 MAXIMUM REPETITIVE PEAK
CHARACTERISTIC REVERSE VOLTAGE AND 600.0
MAXIMUM REPETITIVE PEAK
OFF-STATE VOLTAGE
CTQX CURRENT RATING PER 12.50 AMPERES MAXIMUM ON-STATE
CHARACTERISTIC CURRENT, RMS TOTAL AND 200.00
AMPERES MAXIMUM PEAK ON-STATE
CURRENT, NONREPETITIVE
CTRD POWER RATING PER 40.0 WATTS MAXIMUM PEAK GATE
CHARACTERISTIC POWER DISSIPATION
PRPY PROPRIETARY CHARACTERISTICS MRCS
TTQY TERMINAL TYPE AND QUANTITY 2 PIN AND 1 CASE

________________________________________________________________________

Message: 1
Date: Fri, 30 Jan 2004 00:08:49 -0000
From: "wshawlee2" <walter2@...>
Subject: Looking for obscure HP 1884- xxxx series parts

Hi,
does anybody have some spare TO-3 Hp 1884-0019 parts?
they are SCRs or Triacs used in power supply pre-regulators, RCA was
the manufacturer. I need either the real part number or
some HP parts if avaiable. Not listed anywher in my bench briefs, or
on line archives, so any help appreciated.

many thanks,
walter

sphere research corporation


Looking for obscure HP 1884- xxxx series parts

wshawlee2
 

Hi,
does anybody have some spare TO-3 Hp 1884-0019 parts?
they are SCRs or Triacs used in power supply pre-regulators, RCA was
the manufacturer. I need either the real part number or
some HP parts if avaiable. Not listed anywher in my bench briefs, or
on line archives, so any help appreciated.

many thanks,
walter

sphere research corporation


Consulting work Mixed Signal Test

Chris Freeman
 

开云体育

Just wanted to see if anyone might be interested???
?
Project Location: AZ
Project Name: Test & Debug Engineer - Digital and Analog
Desired Start Date: 02/02/2004
Length of Engagement: 6 Months
Primary Skill: HARDWARE TESTING

Other Skills:
Roles & Responsibilities
POSITION TITLE:? Test and Debug Engineer
?
PROJECT DESCRIPTION:? Candidate will develop and run tests on the IMS
tester to validate and debug a mixed signal AFE for the GPRS/EDGE
market.?
?
DAILY RESPONSIBILITIES:? Candidate will be responsible for following an
execution plan to validate a mixed signal Analog Front End (AFE).? As
issues are identified the individual will be responsible to define tests
and conditions to debug the problems.? Candidate will be working closely
with the design engineering team to close all issues.
Execution plan is already developed but more tests may need to be
developed as needed.?
Must be able to drive hardware, run the front end and understand IMS and
related tools.?
Will work with Engineering group.

?
YEARS OF EXPERIENCE DESIRED:? 5+ years
?
?EXPERTISE LEVEL (JR., MID., SR. ):? Sr.
?
?NECESSARY SKILLS (MUST HAVE):?
?1. Mixed Signal Test experience (with a tester or on a bench)
?2. Mixed Signal Tester experience
?IMS is preferred, but experience with catalyst, S9K, HP93K,
Agilent etc???????? will get the considered by the manager.
3. Analog test experience
4.? A solid understanding of BOTH analog and mixed signal concepts
?including???????? measurement methods.? Good communication skills are a
?must.? Unix
?
?ADDITIONAL SKILLS DESIRED:??
?
Perl, Verilog, Spectre
?
?PRESCREEN QUESTIONS TO ASK:
?1. What is your mixed signal test experience?? (Describe a few
?sentences)
?2. What was your tester experience?? What tester and what did you do
?with it?
?(maintain the tester?? Program the tester?? Push the buttons on the
?tester?)
?
?If they have pretty solid answers for these questions and they meet the
other requirements, please submit the candidate.? Add the answers to the
prescreen questions to the submittal email.

_______________________________________

Chris?Freeman
?Division?Manager
?Oxford?Global?Resources,?Inc.
33320?9th?Ave?South?Suite?150
Federal?Wat,?WA?98003
Tel:?800-260-8844
Fax:?253-835-0660
Website:?
"The Right Talent. Right Now.?"
?
?
?
?