Re: Convert monochrome 5454x scope to color
Hello, can you fund around one LCD with XY imput? I got one dead HP182T mainframe for my S.A some help please.
Thank you all for some imput.
Francesco. ?
?
Sent:?Wednesday, February 02, 2022 at 11:35 AM
From:?"Bill E" <solartron@...> To:[email protected] Subject:?Re: [HP-Agilent-Keysight-equipment] Convert monochrome 5454x scope to color I looked into this a while back. There are significant differences between the CRT and LCD versions, including different main pcbs. It seems the only practical path would be a hack that would convert the CRT scan signals to LCD usable, but you wouldn't have the color info. I solved the problem by getting lucky, found a color 54542 on EPray for $199. "Not working". Apparently it wasn't working because the seller never plugged it in or some such, worked perfectly, all in spec. Now I need something to do with my 2 CRT 542s. |
Re: Convert monochrome 5454x scope to color
I looked into this a while back. There are significant differences between the CRT and LCD versions, including different main pcbs. It seems the only practical path would be a hack that would convert the CRT scan signals to LCD usable, but you wouldn't have the color info. I solved the problem by getting lucky, found a color 54542 on EPray for $199. "Not working". Apparently it wasn't working because the seller never plugged it in or some such, worked perfectly, all in spec. Now I need something to do with my 2 CRT 542s. |
Re: HP 5090B Droitwich receiver documentation wanted
I have never seen a 5090B manual but did upload a scan of my 5090A manual to Mediafire some time ago and have just confirmed the link is still good.....
https://www.mediafire.com/file/u0bf1eips89uo3h/HP_5090A_Ops_and_Service.pdf/file
You could also ask on the on the Time-Nuts mailing list, or check their archives, but discussions there when I bought my 5090B in 2010 confirmed one thing I'd already decided from the 5090A manual, that attempted conversion of the unit itself would probably not be a very good idea:-) At one time I thought perhaps the only difference between the A and B versions might just be the chart recorder on the B but I have seen it suggested there could be other differences, I have not checked that. Since Droitwich changed frequency in 1988 there have been quite a few articles published offering 198KHz to 200 KHz converters but one I particularly liked used the existing 200KHz frequency locked standard as part of the conversion loop and didn't require any additional tuned circuits.
That was published in RadCom in 1989 and a copy is attached.
If that copy doesn't get through I'd be happy to send it direct but again it's not something I've tried, and probably not likely to now, so can't confirm how effective it might be.
Nigel, GM8PZR
HP 5090B Droitwich receiver documentation wanted
From: Donald Prins Date: Tue, 01 Feb 2022 19:01:54 GMT Dear Fellow HP fans, Would anybody have documentation of the receiver available? This receiver and the antenna 15500A provided the standard frequency in the quartz crystal Philips plant at Doetinchem in the Netherlands till Droitwich changed to 198kHz. The plan is to build in a converter for 198 to 200kHz and do the necessary maintenance. A manual for the B model and information on a converter would be very welkome. Yours Donald Prins PE1AHJ |
Re: HP8753C Source Pretune after YIG replacement
I generally try not to kibitz, but your comment about going through the adjustment procedure WITHOUT touching ANYTHING is ABSOLUTELY SPOT ON !!
toggle quoted message
Show quoted text
Quoting peter bunge <bunge.pjp@...>: Are you sure the YIG is dead? How do you know? I suggest you don't adjust |
Re: HP8753C Source Pretune after YIG replacement
Does replacing the YIG without adjusting anything bring the VNA back to life? If not it possibly isn't a bad YIG. On Tue, Feb 1, 2022 at 8:40 PM peter bunge via <bunge.pjp=[email protected]> wrote:
|
Re: HP8753C Source Pretune after YIG replacement
Are you sure the YIG is dead? How do you know? I suggest you don't adjust anything until you know what the problem is. My method of troubleshooting is to go through the adjustments procedure but WITHOUT ADJUSTING ANYTHING. Anything way off indicates the?problem area. Often a failure in a closed loop. Finding a failure in a closed loop can be tricky and requires a knowledge?of the?circuit function.? When you have repaired the problem then you can do the adjustments. Making adjustments without repairing the problem just makes new problems and it will be much more difficult to identify the fault. Many HP problems are due to power supply failure. On Tue, Feb 1, 2022 at 11:24 AM vk2bea via <vk2bea=[email protected]> wrote: I have a dead YIG (5086-7473) in the source of an HP8753C that I am replacing. |
Re: 0.5mm dia pins with solder bucket connection
¿ªÔÆÌåÓýBeen there, done that.? Busted a pin on one of the Viking connectors on the back of a 11713A.? But rather than bother with the connector I just bought another 11713A on eBay for about $40.? Tons on there for dirt cheap these days.? And now I have a parts mule as well.? ? ? ? ? Jim Ford? Sent from my T-Mobile 4G LTE Device -------- Original message -------- From: Mark Bielman <mbielman@...> Date: 2/1/22 1:02 PM (GMT-08:00) Subject: Re: [HP-Agilent-Keysight-equipment] 0.5mm dia pins with solder bucket connection I had to replace a broken pin on one of the Viking connectors on my HP 11713A attenuator controller. Had to buy 50 minimum. Only needed one! No idea if that is what you're looking for. Mark |
Re: HP85101B: looking for for A7 switching regulator schematic
Bruce,
toggle quoted message
Show quoted text
I have the A25 motherboard connections list and parts list. It appears the schematic may never have been available outside HP and that¡¯s a shame. Thanks for your efforts! Steve On Jan 31, 2022, at 5:12 PM, Bruce <bruce@...> wrote: |
Re: 0.5mm dia pins with solder bucket connection
¿ªÔÆÌåÓýI need to connect a ribbon cable to a five way 2mm pitch socket on a PCB (Samtec SQT-105-01-F-S) that accepts 0.5mm dia or squarepins, so want something I can use to replace the normal 2.54mm dupont pins. ? From: [email protected] <[email protected]> On Behalf Of Mark Bielman
Sent: 01 February 2022 21:02 To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] 0.5mm dia pins with solder bucket connection ? What are these for? |
HP 5090B Droitwich receiver documentation wanted
Dear Fellow HP fans,
Would anybody have documentation of the receiver available? This receiver and the antenna 15500A provided the standard frequency in the quartz crystal Philips plant at Doetinchem in the Netherlands till Droitwich changed to 198kHz. The plan is to build in a converter for 198 to 200kHz and do the necessary maintenance. A manual for the B model and information on a converter would be very welkome. Yours Donald Prins PE1AHJ. |
Re: 54503A
Off OP, but along the same lines - is anyone aware of schematics and/or replaceable parts list for the 54522A? Thank you, Radu.? On Tue, Feb 1, 2022 at 8:59 AM N5ZTW via <n5ztw=[email protected]> wrote: Could you please upload the schematics to the files section here. I need them to troubleshoot this issue. |
HP8753C Source Pretune after YIG replacement
I have a dead YIG (5086-7473) in the source of an HP8753C that I am replacing.
The manual says to do the procedure for setting the 'source pretune constants correction'.? The section on setting the 'source default correction constants' says that this must be done before the source pretune; however, this will require me to set the 'RF Output Power Correction Constants' and I do not have the equipment for this step (HPIB power meter). Since I'm just changing the YIG and not the whole source block, do I really need to reset all the souce default CCs? Can I just do the?'source pretune constants correction'? |
Re: Latest KE5FX utilities released
¿ªÔÆÌåÓýThis is an experimental tweak intended to retrieve PN plots from FieldFox spectrum analyzers, which was requested by a user (but not yet tested, as I haven't heard back from him.)? It is called up with Acquire->Agilent N9900.? No other significant changes for the past few months. ? -- john, KE5FX ? ? From: [email protected] [mailto:[email protected]] On Behalf Of ??????? ?????
Sent: Tuesday, February 01, 2022 12:18 AM To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment] Latest KE5FX utilities released ? As i see, some code for N9900 support added to pn.cpp, but there is no appropriate menu item in pn.exe |
Re: Latest KE5FX utilities released
¿ªÔÆÌåÓýHi, A new version of GPIB TOOL KIT. ? ? De?: [email protected] <[email protected]> De la part de Mark Bielman ? I did not see any list of changes, updates, etc. |
Re: 8015A Pulse Generator ("Parts or Repair")
On Sun, Jan 30, 2022 at 04:52 PM, Mark Bielman wrote:
However, the unit creates a LOT of heatYou could check the +26 volt supply. (If any of the other regulators are feeding a 'short' somewhere... then that voltage is supposed to be pulled down.)? All the regulators are inter-related... so if the 26 volt is down... all the others will be down too. It might be the pass transistors getting hot? |