Re: HP 3456a was Re: HP 3478A general questions

 

I hear what your saying about the ebay sales of used gear. Got the Fluke 8050a in today that I took a chance on. The seller claimed to have not tested it, yet took the time to photograph it with the power on and the display showing 0000. When I got it one of the batteries was at 0.00 volts and the entire front end was blown out. Once I replaced about 6 components in the front end and the batteries it's now up and running and appears well within it's rated specs or a little better. This time I lucked out, if it were a hybrid chip for example that was blown I would be looking at investing more to get a questionable piece of gear up and running..hoping that it would meet the specs it once did. This is all not to say I don't mind taking chances.

So with the 3457a how much weight does the Self Test Passed message hold ? I notice many sellers like to post that. I prefer the sellers that show something actually being measured.

Thanks, and happy holidays.

Jeff

On 12/24/2012 1:03 PM, marvgozum wrote:

If both DMM meet your needs, then the chance it will work coming from unknowns via eBay, and easier to maintain DIY is your goal, the 3456a. If you need more updated features including amps but are willing to risk requiring a factory cal, repair and the costs it requires, 3457a.

3468a is not a system class DMM, but a general purpose DMM very much like he 3478a but is much cheaper as it doesn't support the GPIB bus but uses the then popular HP calculator interface. The 3479a is not a DMM, AFAIK.

--- In hp_agilent_equipment@... <mailto:hp_agilent_equipment%40yahoogroups.com>, Jeff Machesky <jeff@...> wrote:Of the two meters, 3456 or 3457 which would be the smarter
purchase ?
In the interest of saving space I'm also looking at the HP 3468a or
3479a. I'm not seeing a major difference between the two except for
perhaps some lower ranges on the 3478a. Any helpful info regarding
those
devices.

If I can score a 3456a or 3457a for a reasonable price then I'll be
heading that direction. At the moment I'm stuck doing projects with
4,000 count B&K meters and a 20,000 DMM on the Tek 2465 which is not in
cal to it's spec. So my purchases will be pretty soon. I have a Fluke
8010 on the way which I'm sure will also need cal.

Thanks,


Re: HP Oldies.

 

Thanks. I'll keep watching eBay and see what comes along.

Regards.

Max. K 4 O DS.

Email: max@...

Transistor site
Vacuum tube site:
Woodworking site
Music site:

To subscribe to the fun with transistors group send an email to.
funwithtransistors-subscribe@...

To subscribe to the fun with tubes group send an email to,
funwithtubes-subscribe@...

To subscribe to the fun with wood group send a blank email to
funwithwood-subscribe@...

----- Original Message -----
From: "petepdx1955" <petepdx1955@...>
To: <hp_agilent_equipment@...>
Sent: Monday, December 24, 2012 5:06 PM
Subject: [hp_agilent_equipment] Re: HP Oldies.



A couple weeks ago was a very very clean 250-A, have you checked the completed items. The seller was only asking something like $50 for it.

Was listed at least the first time with no bidders, didnt see if it went the 2nd time.

260-A's come up at least ever 3-4 months.

My spare parts 260-A's came free from a ham swap meet.

I'd just wait, they will show up again.

-pete

BRL 250-A, HP 250-A, HP 250-B.


--- In hp_agilent_equipment@..., "Max Robinson" <max@...> wrote:

I am looking for a couple of HP oldies. The 260A Q meter and the 250A RX
meter. I can't find any on eBay. These two instruments were carried over
from Boonton when HP bought them out.

Regards.

Max. K 4 O DS.

Email: max@...

Transistor site
Vacuum tube site:
Woodworking site

Music site:

To subscribe to the fun with transistors group send an email to.
funwithtransistors-subscribe@...

To subscribe to the fun with tubes group send an email to,
funwithtubes-subscribe@...

To subscribe to the fun with wood group send a blank email to
funwithwood-subscribe@...



------------------------------------

Yahoo! Groups Links




Re: S11 and S22 comparisons on 8753

J. Forster
 

Worse. It's likely chock full of custom MMIC's, sole sourced by Agilent.
The stuff ceased to be repairable probably more than 20 years ago.

-John

==================

And I'm sure the thing is completely unrepairable except by Agilent,
schematics
are not available, and once it goes out of support that is basically the
end of
that.

On 12/24/2012 8:38 PM, J. Forster wrote:

Agreed.

Note that the 8754A(?) computer based VNA that went to 18 GHz cost
prehaps
$80,000 in 1970 (a guess). Probably more w/ options. That's $450,000 in
today's deflated dollars, so $700,000 is not such a bad deal.

I don't have quite $800k to blow this week after buying Christmas
presents. LOL.

-John

====================

On 25 December 2012 00:24, J. Forster <jfor@...
<mailto:jfor%40quikus.com>> wrote:
You can use a SNA for quick and dirty tests, comparing a known, high
quality, component to the DUT, especially if you have a Storage
Normalizer, but in no way is an SNA a substitute for a VNA.
Agreed. That is why I was surprised when someone said a scalar one was
more accurate.

The only regime where they are used today, AFAIK, ia at frequencies
above
those practical for VNAs, over 40 GHz or more.
Agilent sell a VNA for 110 GHz. At $691,437 for a 4-port model, I
don't expect Agilent sell too many of them! If you buy all the
options, it will be over $800,00.

Dave

--------------------------------------------------------------------------------

No virus found in this message.
Checked by AVG - www.avg.com <>
Version: 10.0.1430 / Virus Database: 2637/5484 - Release Date: 12/24/12


------------------------------------

Yahoo! Groups Links




Re: S11 and S22 comparisons on 8753

Peter Gottlieb
 

And I'm sure the thing is completely unrepairable except by Agilent, schematics are not available, and once it goes out of support that is basically the end of that.

On 12/24/2012 8:38 PM, J. Forster wrote:

Agreed.

Note that the 8754A(?) computer based VNA that went to 18 GHz cost prehaps
$80,000 in 1970 (a guess). Probably more w/ options. That's $450,000 in
today's deflated dollars, so $700,000 is not such a bad deal.

I don't have quite $800k to blow this week after buying Christmas
presents. LOL.

-John

====================

On 25 December 2012 00:24, J. Forster <jfor@...
<mailto:jfor%40quikus.com>> wrote:
You can use a SNA for quick and dirty tests, comparing a known, high
quality, component to the DUT, especially if you have a Storage
Normalizer, but in no way is an SNA a substitute for a VNA.
Agreed. That is why I was surprised when someone said a scalar one was
more accurate.

The only regime where they are used today, AFAIK, ia at frequencies
above
those practical for VNAs, over 40 GHz or more.
Agilent sell a VNA for 110 GHz. At $691,437 for a 4-port model, I
don't expect Agilent sell too many of them! If you buy all the
options, it will be over $800,00.

Dave
--------------------------------------------------------------------------------

No virus found in this message.
Checked by AVG - www.avg.com <>
Version: 10.0.1430 / Virus Database: 2637/5484 - Release Date: 12/24/12


Re: S11 and S22 comparisons on 8753

J. Forster
 

Agreed.

Note that the 8754A(?) computer based VNA that went to 18 GHz cost prehaps
$80,000 in 1970 (a guess). Probably more w/ options. That's $450,000 in
today's deflated dollars, so $700,000 is not such a bad deal.

I don't have quite $800k to blow this week after buying Christmas
presents. LOL.

-John

====================

On 25 December 2012 00:24, J. Forster <jfor@...> wrote:
You can use a SNA for quick and dirty tests, comparing a known, high
quality, component to the DUT, especially if you have a Storage
Normalizer, but in no way is an SNA a substitute for a VNA.
Agreed. That is why I was surprised when someone said a scalar one was
more accurate.

The only regime where they are used today, AFAIK, ia at frequencies
above
those practical for VNAs, over 40 GHz or more.
Agilent sell a VNA for 110 GHz. At $691,437 for a 4-port model, I
don't expect Agilent sell too many of them! If you buy all the
options, it will be over $800,00.

Dave


Re: S11 and S22 comparisons on 8753

David Kirkby
 

On 25 December 2012 00:24, J. Forster <jfor@...> wrote:
You can use a SNA for quick and dirty tests, comparing a known, high
quality, component to the DUT, especially if you have a Storage
Normalizer, but in no way is an SNA a substitute for a VNA.
Agreed. That is why I was surprised when someone said a scalar one was
more accurate.

The only regime where they are used today, AFAIK, ia at frequencies above
those practical for VNAs, over 40 GHz or more.
Agilent sell a VNA for 110 GHz. At $691,437 for a 4-port model, I
don't expect Agilent sell too many of them! If you buy all the
options, it will be over $800,00.

Dave


HP5328a Fan upgrade

 

Hi Folks,

I've been thinking on upgrading my HP5328a's fan wich is so noisy that I cannot make any QSO while it's on.
Anyone ever thought about replacing it with a DC Brushless Computer Fan like ADDA Model AD0812HS?
This fan is quite the same in dimension, it is even a little thinner. Any thougths anyone?


Bas.


Re: S11 and S22 comparisons on 8753

J. Forster
 

You can use a SNA for quick and dirty tests, comparing a known, high
quality, component to the DUT, especially if you have a Storage
Normalizer, but in no way is an SNA a substitute for a VNA.

The only regime where they are used today, AFAIK, ia at frequencies above
those practical for VNAs, over 40 GHz or more.

FWIW,

-John

=================

On 24 December 2012 21:11, laurens_db <laurens101@...> wrote:
A well calibrated VNA is the best way of measuring S11/ S22.
That was my belief too - at least in the context of typical test
equipment. I would not be surprised if there other techniques
applicable to standards labs, which are not too practical for
commerical or amateur use.

I just opened this book:



and looked up scalar network analyzers. By the very title of the book,
you can see it is mainly devoted to VNAs, though there is a bit of
discussion about scalar network analyzers. To quote:


"Scalar network analyzers has the attribute of being very simple to
use, with almost no calibration or setup required. The scalar network
analyzers were designed to be quite flat in frequency response, and a
typical system consisted of one and the input and one at the output of
the DUT. However, for measurements of input or output match, or
impedance, the scalar network analyzer relied on a very high quality
coupler or directional bridge. If there was any cabling, switching or
other test system between the bridge and the DUT, the composite
matches of ALL were measured. There was no additinonal calibration
possible, to remove the effects of the mismatch. As test systems
became more complex and integrated, scalar network analyzers started
to fall from favor and there are virtually none sold today by
commercial instrument manufacturers"


As far as I can tell, the error correction of a VNA offers the ability
to compensate for errors than the scalar network analyzer simply does
not.

A broadband cal kit load is as close to 50Ohm as HP can make it.
Yes, although because of the limitations of broadband loads, sliding
loads are often used at higher frequencies. To once again quote from
Joel Dunsmore's book:

"The load standard is usually the most difficult to produce. <snip
lots> The sliding load, which should more properly be called a sliding
mismatch, is constructed from lengths of precision airline, The centre
conductor of the airline is typically created in such a way that it
can slide into place while the outer conductor is not yet mated, to
allow a beadless connection. The load element is typically not
resistive element, but is more commonly a tapered bead of lossy
material, that essentially makes the airline look like a lossy
element. It is designed to have an impedance which is not quite 50
Ohms, normally in the range of 26-40 dB return loss.

<snip>

"As the sliding load is moved, so its apparent impedance rotates
around the Smith Chart"

There's a diagram showing a full circle on the Smith chart, almost,
but not quite in the centre.It slightly spirals in, as the frequency
(and so loss) is incresed.

"The difference between the computed centre and the actual centre of
the Smith Chart determines the directivity error term"

I think is should be obvious what I stated earlier, that sliding loads
are impractical at lower frequencies. Looking at the manual for the
85054A 'N' cal kit, the minimum frequency of the sliding load is 1.999
GHz.

At 100 MHz (lambda = 3m), the load would need to be 1.5 m long to get
a complete half-wave on a Smith Chart. I suspect you can get away with
less than a full circle, as it only needs 3 points to make a circle,
but I think accuracy would suffer a lot if you could not get an
appreciable part of a circle.


Dave


Re: S11 and S22 comparisons on 8753

David Kirkby
 

On 24 December 2012 21:11, laurens_db <laurens101@...> wrote:
A well calibrated VNA is the best way of measuring S11/ S22.
That was my belief too - at least in the context of typical test
equipment. I would not be surprised if there other techniques
applicable to standards labs, which are not too practical for
commerical or amateur use.

I just opened this book:



and looked up scalar network analyzers. By the very title of the book,
you can see it is mainly devoted to VNAs, though there is a bit of
discussion about scalar network analyzers. To quote:


"Scalar network analyzers has the attribute of being very simple to
use, with almost no calibration or setup required. The scalar network
analyzers were designed to be quite flat in frequency response, and a
typical system consisted of one and the input and one at the output of
the DUT. However, for measurements of input or output match, or
impedance, the scalar network analyzer relied on a very high quality
coupler or directional bridge. If there was any cabling, switching or
other test system between the bridge and the DUT, the composite
matches of ALL were measured. There was no additinonal calibration
possible, to remove the effects of the mismatch. As test systems
became more complex and integrated, scalar network analyzers started
to fall from favor and there are virtually none sold today by
commercial instrument manufacturers"


As far as I can tell, the error correction of a VNA offers the ability
to compensate for errors than the scalar network analyzer simply does
not.

A broadband cal kit load is as close to 50Ohm as HP can make it.
Yes, although because of the limitations of broadband loads, sliding
loads are often used at higher frequencies. To once again quote from
Joel Dunsmore's book:

"The load standard is usually the most difficult to produce. <snip
lots> The sliding load, which should more properly be called a sliding
mismatch, is constructed from lengths of precision airline, The centre
conductor of the airline is typically created in such a way that it
can slide into place while the outer conductor is not yet mated, to
allow a beadless connection. The load element is typically not
resistive element, but is more commonly a tapered bead of lossy
material, that essentially makes the airline look like a lossy
element. It is designed to have an impedance which is not quite 50
Ohms, normally in the range of 26-40 dB return loss.

<snip>

"As the sliding load is moved, so its apparent impedance rotates
around the Smith Chart"

There's a diagram showing a full circle on the Smith chart, almost,
but not quite in the centre.It slightly spirals in, as the frequency
(and so loss) is incresed.

"The difference between the computed centre and the actual centre of
the Smith Chart determines the directivity error term"

I think is should be obvious what I stated earlier, that sliding loads
are impractical at lower frequencies. Looking at the manual for the
85054A 'N' cal kit, the minimum frequency of the sliding load is 1.999
GHz.

At 100 MHz (lambda = 3m), the load would need to be 1.5 m long to get
a complete half-wave on a Smith Chart. I suspect you can get away with
less than a full circle, as it only needs 3 points to make a circle,
but I think accuracy would suffer a lot if you could not get an
appreciable part of a circle.


Dave


Re: HP Oldies.

 

Nothing special by today's standards but in 1952 it was. I'll see if I can dig up the information that was sent to me.

Here is a description of the last of the series the H/J


-pete

--- In hp_agilent_equipment@..., Peter Gottlieb <hpnpilot@...> wrote:

What was so special about the 202? Are today's generators as good?

On 12/24/2012 6:27 PM, petepdx1955 wrote:

I've been adding to my collection of HP acquisitions, from what
I've been able to find in the search of patents BRC had some interesting on
creating FM modulation. Their 202 series FM generators were the 'standard' for
anyone doing work on VHF FM which in the 60's for telemetry was a big money
maker. And if you were designing for consumer FM you bought a 202.

And of course the Q-Meter was a big seller.

--- In hp_agilent_equipment@...
<mailto:hp_agilent_equipment%40yahoogroups.com>, "Richard Knoppow"
<dickburk@> wrote:


----- Original Message -----
From: "David DiGiacomo" <daviddigiacomo@>
To: <hp_agilent_equipment@...
<mailto:hp_agilent_equipment%40yahoogroups.com>>
Sent: Friday, December 21, 2012 3:49 PM
Subject: Re: [hp_agilent_equipment] HP Oldies.


On Fri, Dec 21, 2012 at 1:22 PM, Dave Daniel
<kc0wjn@> wrote:
Wow. I didn't know HP bought Boonton. I always liked
Boonton
instruments, probably because I was born in Boonton. When
did HP buy them?

Dave
This is confusing (at least to me), because there was
Boonton
Electronics, Boonton Measurements (usually just called
Measurements),
and Boonton Radio. HP bought Boonton Radio, but not the
other two.
Most of the familiar Boonton instruments are from Boonton
Electronics.
Boonton Electronics made sensitive electronic
voltmeters and some other equipment. Measurements Corp made
voltmeters and signal generators. I have a frequency
calibrator/marker made by Measurements Corp. Boonton Radio
Corp made the Q-Meter, which they originated, the RX-Meter,
which is a consolidation of an RF bridge, signal generator,
and detector in one box, and a variety of signal generators,
mainly FM, and test sets for air navigation equipment.
There was also Aircraft Radio Corporation or ARC, which
was a pioneer in airborne radio equipment. There were a
couple of other companies too but my memory is not very
reliable about them.
-hp- bought only Boonton Radio Corporation. I don't
know what they wanted. They continued to build the Q-Meter
and RX-Meter for a time and a small VHF signal generator,
originally sold under the Boonton name and later as an -hp-
product.
At the time -hp- bought Boonton they were buying a lot
of small companies.


--
Richard Knoppow
Los Angeles
WB6KBL
dickburk@

--------------------------------------------------------------------------------

No virus found in this message.
Checked by AVG - www.avg.com <>
Version: 10.0.1430 / Virus Database: 2637/5483 - Release Date: 12/24/12


Re: HP Oldies.

Peter Gottlieb
 

What was so special about the 202? Are today's generators as good?

On 12/24/2012 6:27 PM, petepdx1955 wrote:

I've been adding to my collection of HP acquisitions, from what
I've been able to find in the search of patents BRC had some interesting on creating FM modulation. Their 202 series FM generators were the 'standard' for anyone doing work on VHF FM which in the 60's for telemetry was a big money maker. And if you were designing for consumer FM you bought a 202.

And of course the Q-Meter was a big seller.

--- In hp_agilent_equipment@... <mailto:hp_agilent_equipment%40yahoogroups.com>, "Richard Knoppow" <dickburk@...> wrote:


----- Original Message -----
From: "David DiGiacomo" <daviddigiacomo@...>
To: <hp_agilent_equipment@...
<mailto:hp_agilent_equipment%40yahoogroups.com>>
Sent: Friday, December 21, 2012 3:49 PM
Subject: Re: [hp_agilent_equipment] HP Oldies.


On Fri, Dec 21, 2012 at 1:22 PM, Dave Daniel
<kc0wjn@...> wrote:
Wow. I didn't know HP bought Boonton. I always liked
Boonton
instruments, probably because I was born in Boonton. When
did HP buy them?

Dave
This is confusing (at least to me), because there was
Boonton
Electronics, Boonton Measurements (usually just called
Measurements),
and Boonton Radio. HP bought Boonton Radio, but not the
other two.
Most of the familiar Boonton instruments are from Boonton
Electronics.
Boonton Electronics made sensitive electronic
voltmeters and some other equipment. Measurements Corp made
voltmeters and signal generators. I have a frequency
calibrator/marker made by Measurements Corp. Boonton Radio
Corp made the Q-Meter, which they originated, the RX-Meter,
which is a consolidation of an RF bridge, signal generator,
and detector in one box, and a variety of signal generators,
mainly FM, and test sets for air navigation equipment.
There was also Aircraft Radio Corporation or ARC, which
was a pioneer in airborne radio equipment. There were a
couple of other companies too but my memory is not very
reliable about them.
-hp- bought only Boonton Radio Corporation. I don't
know what they wanted. They continued to build the Q-Meter
and RX-Meter for a time and a small VHF signal generator,
originally sold under the Boonton name and later as an -hp-
product.
At the time -hp- bought Boonton they were buying a lot
of small companies.


--
Richard Knoppow
Los Angeles
WB6KBL
dickburk@...
--------------------------------------------------------------------------------

No virus found in this message.
Checked by AVG - www.avg.com <>
Version: 10.0.1430 / Virus Database: 2637/5483 - Release Date: 12/24/12


Looking for a clean 11 x 17" 704X recorder electrostatic bed

 

I'm thinking of getting a 704X for "fun". But the one being offered has a delaminated e'staic bed.

Anyone have one for ???

-pete


Re: HP Oldies.

 

I've been adding to my collection of HP acquisitions, from what
I've been able to find in the search of patents BRC had some interesting on creating FM modulation. Their 202 series FM generators were the 'standard' for anyone doing work on VHF FM which in the 60's for telemetry was a big money maker. And if you were designing for consumer FM you bought a 202.

And of course the Q-Meter was a big seller.

--- In hp_agilent_equipment@..., "Richard Knoppow" <dickburk@...> wrote:


----- Original Message -----
From: "David DiGiacomo" <daviddigiacomo@...>
To: <hp_agilent_equipment@...>
Sent: Friday, December 21, 2012 3:49 PM
Subject: Re: [hp_agilent_equipment] HP Oldies.


On Fri, Dec 21, 2012 at 1:22 PM, Dave Daniel
<kc0wjn@...> wrote:
Wow. I didn't know HP bought Boonton. I always liked
Boonton
instruments, probably because I was born in Boonton. When
did HP buy them?

Dave
This is confusing (at least to me), because there was
Boonton
Electronics, Boonton Measurements (usually just called
Measurements),
and Boonton Radio. HP bought Boonton Radio, but not the
other two.
Most of the familiar Boonton instruments are from Boonton
Electronics.
Boonton Electronics made sensitive electronic
voltmeters and some other equipment. Measurements Corp made
voltmeters and signal generators. I have a frequency
calibrator/marker made by Measurements Corp. Boonton Radio
Corp made the Q-Meter, which they originated, the RX-Meter,
which is a consolidation of an RF bridge, signal generator,
and detector in one box, and a variety of signal generators,
mainly FM, and test sets for air navigation equipment.
There was also Aircraft Radio Corporation or ARC, which
was a pioneer in airborne radio equipment. There were a
couple of other companies too but my memory is not very
reliable about them.
-hp- bought only Boonton Radio Corporation. I don't
know what they wanted. They continued to build the Q-Meter
and RX-Meter for a time and a small VHF signal generator,
originally sold under the Boonton name and later as an -hp-
product.
At the time -hp- bought Boonton they were buying a lot
of small companies.


--
Richard Knoppow
Los Angeles
WB6KBL
dickburk@...


Re: HP Oldies.

 

There were two companies with Boonton in their name

Boonton Electronics. Now a division of a British company boonton.com if interested.

Their two biggest contributions were a C and L bridges that ran at 1 MHz, and a power meter head using diodes.

Boonton Radio Corporation or BRC. These are the guys HP bought. The Q-Meter is prob the biggest contribution, but they did a few other things very well one of which was generators that could FM better then any one else at the time.

The area around Boonton was quite the concentration, all basically springing from a company called Ferris Instruments. Ballentine was another off shoot.

Another company not into instruments but in the same area was Aircraft Radio Corp, or ARC.

--- In hp_agilent_equipment@..., Dave Daniel <kc0wjn@...> wrote:

Wow. I didn't know HP bought Boonton. I always liked Boonton
instruments, probably because I was born in Boonton. When did HP buy them?

Dave


On 12/21/2012 12:59 PM, Max Robinson wrote:

I am looking for a couple of HP oldies. The 260A Q meter and the 250A RX
meter. I can't find any on eBay. These two instruments were carried over
from Boonton when HP bought them out.

Regards.

Max. K 4 O DS.

Email: max@... <mailto:max%40maxsmusicplace.com>

Transistor site
Vacuum tube site:
Woodworking site

Music site:

To subscribe to the fun with transistors group send an email to.
funwithtransistors-subscribe@...
<mailto:funwithtransistors-subscribe%40yahoogroups.com>

To subscribe to the fun with tubes group send an email to,
funwithtubes-subscribe@...
<mailto:funwithtubes-subscribe%40yahoogroups.com>

To subscribe to the fun with wood group send a blank email to
funwithwood-subscribe@...
<mailto:funwithwood-subscribe%40yahoogroups.com>






Re: HP Oldies.

 

A couple weeks ago was a very very clean 250-A, have you checked the completed items. The seller was only asking something like $50 for it.

Was listed at least the first time with no bidders, didnt see if it went the 2nd time.

260-A's come up at least ever 3-4 months.

My spare parts 260-A's came free from a ham swap meet.

I'd just wait, they will show up again.

-pete

BRL 250-A, HP 250-A, HP 250-B.

--- In hp_agilent_equipment@..., "Max Robinson" <max@...> wrote:

I am looking for a couple of HP oldies. The 260A Q meter and the 250A RX
meter. I can't find any on eBay. These two instruments were carried over
from Boonton when HP bought them out.

Regards.

Max. K 4 O DS.

Email: max@...

Transistor site
Vacuum tube site:
Woodworking site

Music site:

To subscribe to the fun with transistors group send an email to.
funwithtransistors-subscribe@...

To subscribe to the fun with tubes group send an email to,
funwithtubes-subscribe@...

To subscribe to the fun with wood group send a blank email to
funwithwood-subscribe@...


Wanted: HP 8554B rf section for 141T

 

Hello,
I am looking for a HP 8554B rf section for my 141T spectrum analyzer in working condition at reasonable cost. I am also looking for a HP 8444 tracking generator to go with it.
Shipping to Germany.
vy 73 Heinz DH2FA, KM5VT


Re: S11 and S22 comparisons on 8753

laurens_db
 

A well calibrated VNA is the best way of measuring S11/ S22.

A broadband cal kit load is as close to 50Ohm as HP can make it.

A slight mismatch at the end of an air line will allow you to normalise the return loss measurements, but not a full correction (the port match and directivities are not resolvable with this method IIRC)

--- In hp_agilent_equipment@..., Brooke Clarke <brooke@...> wrote:

Hi:

The most accurate way of characterizing S11 or S22 is to use a scalar network analyzer with a bridge and precision air
line. The cal load is a precision load that's just slightly off from 50.0 Ohms but how much off doesn't matter.
It's far more accurate than a VNA. The key idea is that the air line is exactly 50.0 Ohms and the mismatch causes
ripple above and below that so the center of the ripples is where the location of 50.0 Ohms.


Have Fun,

Brooke Clarke



hp_agilent_equipment@... wrote:
Re: S11 and S22 comparisons on 8753


Re: S11 and S22 comparisons on 8753

David Kirkby
 

On 24 December 2012 19:23, Brooke Clarke <brooke@...> wrote:
Hi:

The most accurate way of characterizing S11 or S22 is to use a scalar network analyzer with a bridge and precision air
line. The cal load is a precision load that's just slightly off from 50.0 Ohms but how much off doesn't matter.
It's far more accurate than a VNA.
I don't claim to know much about scaler network analyzers, so what I
say might be wrong.

I don't see how you can consider a *scaler* network analyzer able to
characterise S11 and S22, since both S11 and S22 require both
magnitude and phase information.

I believe the things you refer which have an impedance close to, but
not exactly 50 Ohms are generally known as sliding loads, though I
suppose they might have other names.

I do have a few precision airlines which are machined very accurately.
I've got a couple of 50 Ohm ones, and a couple which are stepped from
50 Ohms to 25 Ohms. These are part of VNA *verification* kits, so they
need to be very accurate.

I understand the weak point of calibration kits is the loads - hence
sliding loads are used at higher frequencies.

Dave


HP 3456a was Re: HP 3478A general questions

marvgozum
 

If both DMM meet your needs, then the chance it will work coming from unknowns via eBay, and easier to maintain DIY is your goal, the 3456a. If you need more updated features including amps but are willing to risk requiring a factory cal, repair and the costs it requires, 3457a.

3468a is not a system class DMM, but a general purpose DMM very much like he 3478a but is much cheaper as it doesn't support the GPIB bus but uses the then popular HP calculator interface. The 3479a is not a DMM, AFAIK.


--- In hp_agilent_equipment@..., Jeff Machesky <jeff@...> wrote:Of the two meters, 3456 or 3457 which would be the smarter

purchase ?
In the interest of saving space I'm also looking at the HP 3468a or
3479a. I'm not seeing a major difference between the two except for
perhaps some lower ranges on the 3478a. Any helpful info regarding those
devices.

If I can score a 3456a or 3457a for a reasonable price then I'll be
heading that direction. At the moment I'm stuck doing projects with
4,000 count B&K meters and a 20,000 DMM on the Tek 2465 which is not in
cal to it's spec. So my purchases will be pretty soon. I have a Fluke
8010 on the way which I'm sure will also need cal.

Thanks,


Re: S11 and S22 comparisons on 8753

 

Hi:

The most accurate way of characterizing S11 or S22 is to use a scalar network analyzer with a bridge and precision air line. The cal load is a precision load that's just slightly off from 50.0 Ohms but how much off doesn't matter.
It's far more accurate than a VNA. The key idea is that the air line is exactly 50.0 Ohms and the mismatch causes ripple above and below that so the center of the ripples is where the location of 50.0 Ohms.


Have Fun,

Brooke Clarke



hp_agilent_equipment@... wrote:

Re: S11 and S22 comparisons on 8753