开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育

Translation Specification Exception with Hyperion 4.3.9; Hercules 3.13 ok


 

Hi,

Wondering if anyone else has run into this...
While IPLing ZVSE V4, right after Power begins initializing, a "SYSTEM HAS ENTERED A HARD WAIT <====TRANSLATION SPECIFICATION EXCEPTION" (see attached) occurs with Hyperion v4.3.9999.0-SDL. This happens with a first level VSE or as a guest under VM. ? It works fine on Hercules v3.13. Perhaps it is something simple I've overlooked.
?
?Thanks!
?- Mike


 

Mike wrote:

Wondering if anyone else has run into this...
While IPLing ZVSE V4, right after Power begins initializing,
a "SYSTEM HAS ENTERED A HARD WAIT <====TRANSLATION SPECIFICATION
EXCEPTION" (see attached) occurs with Hyperion v4.3.9999.0-SDL.
This happens with a first level VSE or as a guest under VM.
It works fine on Hercules v3.13. Perhaps it is something simple
I've overlooked.
OR... perhaps you're using a version of Hyperion 4.3 that doesn't have the PIC 12 fix? (committed on 6/16/2020):

Revision: a774fc6fd5ae72a1d70aa8f7812d3dcfc7719f8b
Author: Fish (David B. Trout) <fish@...>
Date: 6/16/2020 5:07:19 PM
Message: Translation Specification PIC 12 (temporary?) fix
Refer to GitHub Issue #275(*) for details.

Please provide a COMPLETE Hercules log showing the *exact* version of Hercules you are using (v4.3.9999 is not an exact version; you need to build from a git clone of the repository, not from the .zip source file) as well as a complete copy of your Hercules configuration file.

It would also help to know the exact version of z/VSE you're using (and where you got it from!) as well as what the exact version of VM you're using too (and where you got it from).

Thanks.

(*)

Yes, the problem was reported against z/OS 2.4, but the bug is not specific to any particular operating system. It was a bug in our Address Translation logic which would affect any operating system using DAT, including z/VSE.

--
"Fish" (David B. Trout)
Software Development Laboratories

mail: fish@...