Re: How to delete BSAM file on DOS/VS
By Harold Grovesteen · #533 ·
Re: How to delete BSAM file on DOS/VS
Hi, Harold and Piotr, From what I recall, from the last century, it was probably the 1980s the last time I actually worked with DOS/VSE at all "for real"... and it was a long time ago. The way
By Mark Waterbury · #532 ·
Re: Some questions about BSAM files on DOS/VS
@Steen I use DITTO very often - to check VTOC, labels, read BSAM file etc. I like it very much and show my students how to use it. But in this case I need to understand the sysem's behaviore. It seems
By Piotr Kolasiński · #531 ·
Re: Some questions about BSAM files on DOS/VS
Fish thanks for explanation but ... it is different than results of my test. I have access to z/VSE 6.1 and wrote the program in cobol, which inloop wruet 80 bytes records with increnebted counter
By Piotr Kolasiński · #530 ·
Re: How to delete BSAM file on DOS/VS
Eddy Balem wrote: I was going to mention that too, BUT... It's a lot easier to simply add the new devices to the supervisor (and then shutdown and re-ipl the new supervisor) than it is to have to
By Fish Fish · #529 ·
Re: How to delete BSAM file on DOS/VS
Just one minor point,you don't need to rebuild the DOS or DOS/VS supervisor to add devices. You can use Add and Del statements at ipl time, subject to the limit specified in the original build .
By Eddy Balem · #528 ·
Re: How to delete BSAM file on DOS/VS
Harold Grovesteen wrote: I would to add to that, that due to this need for manually maintaining the location of all datasets (files) on the system, many shops wrote their own (or used someone else's)
By Fish Fish · #527 ·
Re: Some questions about BSAM files on DOS/VS
Hi, A utility like DITTO might be useful in this case as it can perform a lot of file manipulations on different media, e.g: dasd and tape. Regard, Steen
By Steen Hansen · #526 ·
Re: How to delete BSAM file on DOS/VS
I worked on DOS/VS systems back in the mid- to late 1970's. While DOS/VS has some extent protections as mentioned, actual management of space on volumes is manually performed.? This was usually
By Harold Grovesteen · #525 ·
Re: Some questions about BSAM files on DOS/VS
Hi, Rene, FYI, OS/360, OS/VS1, and OS/VS2 (SVS and MVS) also had "expiration date protection" of datasets available.? It was mainly used for tape datasets, but it could also be used for DASD
By Mark Waterbury · #524 ·
Re: Some questions about BSAM files on DOS/VS
Fish, Mark, Thanks a lot for this information! I always love to learn something new, specially from people who work on DOS/VS in the past. Cheers, Rene FERLAND, Montreal
By René Ferland · #523 ·
Re: Some questions about BSAM files on DOS/VS
Hi, Rene and Piotr, From what I recall, from the last century, it was probably the 1980s the last time I actually worked with DOS/VSE at all "for real"... and it was a long time ago. The way DOS/360
By Mark Waterbury · #522 ·
Re: Some questions about BSAM files on DOS/VS
Piotr Kolasinski wrote: There are no stupid questions if they are asked. It is only when you don't ask your question that it becomes stupid. ;-) No. If the file is never OPENED, it will never be
By Fish Fish · #521 ·
Re: Some questions about BSAM files on DOS/VS
Me neither, before I asked the same question as you in this group. :-) I can't say for sure, but I would not be surprised if DISP=DELETE on MVS just delete the entries in the catalog and VTOC, not
By René Ferland · #520 ·
Re: Some questions about BSAM files on DOS/VS
Thanks Rene! I never heard about this tool . It's really strange that for manage space on dasd volume we have to use "diagnostic" tool (as it is defined in last z/VSE documentation). In real that is
By Piotr Kolasiński · #519 ·
Re: Some questions about BSAM files on DOS/VS
I can't answer for your questions 2 and 3 (Fish, can you?). But for 1 above, I use a program called IKQVDU. It can be run in a batch job or interactively on the console. I used the latter. It goes on
By René Ferland · #518 ·
Some questions about BSAM files on DOS/VS
Hello everybody I know that my questions may be stupid but .. 1. How to remove (delete) BSAM dataset from DASD? In MVS I just use DISP=DELETE and IEFBR14, but how to remove sequenced dataset,
By Piotr Kolasiński · #517 ·
Re: POWER II source distribution
Hi, I know this thread is somewhat old, but I had exactly the same experience yesterday and managed to recover from it. I checked both the original POWER input tape as well as the newly created blank
By Steen Hansen · #515 ·
File /hello_99bottles_pi.zip uploaded #file-notice
The following files and folders have been uploaded to the Files area of the [email protected] group. * /hello_99bottles_pi.zip ( /g/H390-DOSVS/files/hello_99bottles_pi.zip
By Group Notification <noreply@...> · #514 ·
Re: Missing module?
Here it is: * $$ JOB JNM=HELLO,CLASS=0,DISP=D * $$ LST CLASS=A,DISP=D,JSEP=0 // JOB HELLO // OPTION LINK // EXEC ASSEMBLY PRINT NOGEN HELLO? ? START 0 BEGIN? ? BALR? 3,0 USING *,3 OPEN?
By René Ferland · #513 ·