¿ªÔÆÌåÓý


Hit RA Safety limit and couldn't move away from it.

 

¿ªÔÆÌåÓý

I was resetting the worm mesh on my G11 (I¡®d been getting RA stalls) and during testing I hit the RA safety limit.?? My problem is that I couldn¡¯t use the arrow keys on the HC to move the mount after that.? Surely I should be able to move out of the limit?

?

What am I missing?

?

David

?


Re: February 29th abnormality

 

Just a quick follow-up.? I fired up Gemini last night and the date on the HC was accurate.


Re: Response difference between L6.10 and L6.01

 

Paul,
?
I'm sure I've found the solution to solve this issue, though I don't know exactly the mechanism of the problem.
My Gemini-2 for CG-11 (SLW&OPW) was directly connected to my NUC #2 without router.? I assigned the different network to this connection.? Then NUC #2 mounted on OTA was connected to my home network through Wi-Fi.
I've changed to make the Gemini-2 unit join the home network by connecting to a Wi-Fi router.? The unit now becomes one of other devices on the home network.
Under this configuration, I see no response delay.? Still I don't understand why the direct connection between the unit and X270 / NUC #1 doesn't show this issue.
For the time being, I will keep this configuration for my CG-11's Gemini-2.
?
Best regards,
?
masami


Re: Response difference between L6.10 and L6.01

 

Paul,
?
Following your reply, I've changed my PC, which is connected to CG-11's Gemini-2, to other PCs.? I've got very interesting results.
?
#1 Gemini-2 === Intel NUC #2: has slow response problems
#2 Gemini-2 === ThinkPad X270: no problem, immediate response
#3 Gemini-2 === Intel NUC #1: ?no problem, immediate response
?
Actually NUC #2 and NUC #1 are basically identical hardware and installed software is also same.? X270 has the same software configuration as well.
So I think the problem is not Gemini-2 nor ASCOM Gemini Telescope Driver, but NUC #2 hardware or might be some software configuration difference.
I will look into NUC #2 further.
I appreciate your quick support.
?
masami


Re: PEC keeps turning off

 

I may have done those resets as well since they are in the afternoon right before I grab the log.?


Re: Response difference between L6.10 and L6.01

 

On Sat, Mar 1, 2025 at 10:11 PM, YAMADA masami wrote:
For CG-11's Gemini-2, I've noticed that the response time when I select "Configure PEC" on virtual HC is very slow, "Configure PEC" window appears after more than 10 seconds have passed.? Also after I select "Set PEC Period", again its confirmation window appears after 15 seconds or so, following "Not Responding" message in the title bar.
Hi masami,
?
The error in the ASCOM log shows that the driver can't connect to Gemini using FTP protocol (this is used to retrieve the list of PEC files stored on the SD card):
?
10:48:30.983 Exception? ? ?TID:1 [Error]: System.Net.WebException: Unable to connect to the remote server at System.Net.FtpWebRequest.GetResponse()
?
Not sure what's causing this, other than possibly something on your network or PC blocking FTP ports 20 and 21, or some other network permission not allowing FTP access from your PC.


Response difference between L6.10 and L6.01

 

Hi,
?
I have two Gemini-2 units.? One for my CG-11 (OPW+SLW upgraded) and G-11 (OPW only).
For CG-11's Gemini-2, I've noticed that the response time when I select "Configure PEC" on virtual HC is very slow, "Configure PEC" window appears after more than 10 seconds have passed.? Also after I select "Set PEC Period", again its confirmation window appears after 15 seconds or so, following "Not Responding" message in the title bar.
I've carried out the same test for G-11's Gemini-2.? When I press "Configure PEC", almost immediately "Configure PEC" window appears.? There is no time lag.
I used the same ASCOM Gemini Telescope driver 1.1.28.0.? But the FW versions are different.
?
For CG-11: Gemini unit ver. 6.10,? HC ver. 1.63
For G-11: Gemini unit ver. 6.01, HC ver. 1.60
?
I put Gemini Troubleshooting Reporter logs in Yamada-2 folder in User_Logs_error_files_and_suggestions.
?
Thanks in advance,
?
masami


Re: Gemini-2 partially locked-up!?

 

Hi Paul,
?
Next time I will use Gemini Troubleshooting Reporter.? According to the forecast, the weather here will not be cooperative in a few weeks or so.
By the way, I don't know this issue is related to my original lock-up thread, but I will raise another thread regarding Cofigure PEC menu.? There is a difference between my Gemini-2 for CG-11 and for G-11.
?
Thanks in advance,
?
masami


Re: PEC keeps turning off

 

On Sat, Mar 1, 2025 at 11:09 AM, Seokman Han wrote:
3 days ago, I was trying to figure out why my mount points to the wrong direction and I found out I set reverse RA.
?
Did you also do a few reboots/resets on Feb 28? It looks like there were two WD Resets on that date, also.
?


Re: PEC keeps turning off

 

Hi Paul,
?
I will follow your suggestion. I have cloudy nights for the next week, I can try in the future.
Looking at those timestamp of events, they may be I was doing the reset. I used the web UI to cold restart the mount. what I noticed was that the mount kept rebooting if I stayed on the web page for cold reboot. I think the web browser kept refresh the web page when it cannot load the page. When it load web page after boot, it sends reboot commands again by refreshing the web page. 3 days ago, I was trying to figure out why my mount points to the wrong direction and I found out I set reverse RA.
?
Thank you,
Seokman


Re: Gemini-2 partially locked-up!?

 

Hi masami,
?
Like I asked Seokman, can you please go to the Gemini.NET virtual hand controller, connect to Gemini and collect a troubleshooter log zip file and upload it here? Seokman appears to have a number of WD Reset events in his logs, which often indicates a problem with memory and settings -- possibly a bad 3v battery.
?
?
Regards,
?
? -Paul


Re: PEC keeps turning off

 

On Fri, Feb 28, 2025 at 05:41 PM, Seokman Han wrote:
Hi Paul,
?
I uploaded the reporting Zip file to files section.
One more thing I noticed is that when I click on Setup -> Advanced Gemini Settings..., I get an error message saying 'Communications error' However I can still click on any of 'Get Settings From Gemini' from the settings screen and it gets settings from the Gemini.
?
Thank you,
Seokman
?
Hi Seokman,

Thanks for uploading this! Looking into Gemini status log, it appears you've been experiencing very frequent restarts after a watchdog reset events (WD Reset). Here are some of the latest:
26264.88672 PECWormPos 7858, Restarted after WD Reset. UTC Date_Time 2025.02.26_04:57:01
26288.96875 PECWormPos 8755, Restarted after WD Reset. UTC Date_Time 2025.02.26_04:57:25
73736.87500 PECWormPos 8755, Restarted after WD Reset. UTC Date_Time 2025.02.26_18:06:03
17371.02344 PECWormPos 8755, Cold Started. UTC Date_Time 2025.02.27_02:25:14
25675.89844 PECWormPos 37, Cold Start enforced. UTC Date_Time 2025.02.28_04:39:21
67953.90625 PECWormPos 40, Cold Start enforced. UTC Date_Time 2025.02.28_16:22:04
85109.25000 PECWormPos 10592, Cold Started. UTC Date_Time 2025.02.28_21:07:12
3077.89062 PECWormPos 22084, Restarted after WD Reset. UTC Date_Time 2025.02.28_22:19:49
3241.95703 PECWormPos 12939, Restarted after WD Reset. UTC Date_Time 2025.02.28_22:22:33
?
I would suggest you try the following sequence of tests:
?
1. Replace the internal 3v battery with a new one
2. Reset Gemini to all default settings
3. After populating all the right settings, try to see if the problem re-occurs
4. If yes, you may want to try to re-flash Gemini firmware, then repeat at step 2.
5. If that doesn't work, I'll need some help from Rene or one of our repairers to see if there's a problem with Gemini memory.
?
Regards,
?
? -Paul
?


Re: Gemini-2 partially locked-up!?

 

I do see the same pattern on my ASCOM log file.
?
01:57:21.910 UDP connection ? ? ? ? ? ?TID:11 [2]: gemini, 11110
01:57:21.910 Looking up DHCP name ? ? ?TID:11 [2]: gemini
01:57:23.762 IT:PulseGuide5 ? ? ? ? ? ?TID:9 [Enter] guideWest, 160
01:57:23.762 IT:CanPulseGuide.Get ? ? ?TID:9 [Enter] True
01:57:24.638 Exception ? ? ? ? ? ? ? ? TID:11 [Error]: System.Net.Sockets.SocketException (0x80004005): No such host is known[0D][0A] ? at System.Net.Dns.GetAddrInfo(String name)[0D][0A] ? at System.Net.Dns.InternalGetHostByName(String hostName, Boolean includeIPv6)[0D][0A] ? at System.Net.Dns.GetHostAddresses(String hostNameOrAddress)[0D][0A] ? at ASCOM.GeminiTelescope.Gemini5Hardware.ConnectToEthernet() in C:\Users\ypa\Documents\Ascom.Gemini.Telescope\GeminiTelescope\Gemini5Hardware.cs:line 242[0D][0A] ? at ASCOM.GeminiTelescope.GeminiHardwareBase.Connect() in C:\Users\ypa\Documents\Ascom.Gemini.Telescope\GeminiTelescope\GeminiHardware.cs:line 2883
01:57:24.648 IT:Connected.Set ? ? ? ? ?TID:11 [Enter] False
01:57:24.648 Disconnect() ? ? ? ? ? ? ?TID:11 [Enter]?
01:57:24.648 Current connect state ? ? TID:11 [2]: False
01:57:24.648 Remaining clients ? ? ? ? TID:11 [2]: 0
01:57:24.648 No more clients, disconne TID:11 [2]:?
01:57:24.648 Closing serial port ? ? ? TID:11 [2]:?
01:57:24.648 Serial port closed ? ? ? ?TID:11 [2]:?
01:57:24.648 Closing Ethernet connecti TID:11 [2]:?
01:57:24.648 DisconnectToEthernet ? ? ?TID:11 [Enter]?
01:57:24.648 DisconnectToEthernet ? ? ?TID:11 [Exit]?
01:57:24.648 Closed Ethernet connectio TID:11 [2]:?
01:57:24.649 Closing pass-through port TID:11 [2]:?
01:57:24.649 Pass-through port closed ?TID:11 [2]:?
01:57:24.649 Disconnect() ? ? ? ? ? ? ?TID:11 [Exit]?
01:57:24.649 IT:Connected.Set ? ? ? ? ?TID:11 [Exit] False
01:57:26.382 IT:PulseGuide5 ? ? ? ? ? ?TID:11 [Enter] guideWest, 40
01:57:26.383 IT:CanPulseGuide.Get ? ? ?TID:11 [Enter] True
01:57:28.985 IT:PulseGuide5 ? ? ? ? ? ?TID:11 [Enter] guideWest, 54
01:57:28.986 IT:CanPulseGuide.Get ? ? ?TID:11 [Enter] True
01:57:31.594 IT:PulseGuide5 ? ? ? ? ? ?TID:11 [Enter] guideWest, 64
01:57:31.595 IT:CanPulseGuide.Get ? ? ?TID:11 [Enter] True
?
It looks like it got disconnected at 1:57:24 because my computer could not communicate with Gemini any longer, but the guiding command continued until 02:31:50
?
Paul


Re: Gemini-2 partially locked-up!?

 

Hi Paul,
?
Thank you for your guick feedback.
Yes, after I found my Gemini-2 was disconnected, I tried to connect to it from the virtual HC several times.? But no avail.
At that time, as I wrote before, its HC was alive, and I could confirm its network IP address (192.168.111.22) unchanged from the HC.? However I could not move the mount by pressing the button.? Then I powered off and on the unit, I could connect to Gemini through the remote PC, and move the mount as usual.? Because It was late, I didn't test it further.? I think its internal battery is OK.? Is it better to reset the unit by removing the battery and/or reflash it, though I don't want to lose its PEC data?
?
Best regards,
?
masami
?


Re: PEC keeps turning off

 

Hi Paul,
?
I uploaded the reporting Zip file to files section.
One more thing I noticed is that when I click on Setup -> Advanced Gemini Settings..., I get an error message saying 'Communications error' However I can still click on any of 'Get Settings From Gemini' from the settings screen and it gets settings from the Gemini.
?
Thank you,
Seokman


Re: Gemini-2 partially locked-up!?

 

On Fri, Feb 28, 2025 at 01:37 PM, YAMADA masami wrote:
During my guiding session, suddenly PHD2 reported that the mount was not connected on the remote desktop screen.? Indeed the virtual HC's connect button showed "connect."??So I went to the roof and checked the status of the mount.? The unit was powered on and HC's menus were responsive, but the mount failed to move when I pressed the button.? After powering the unit again, it returned normal so far.
I remember this is the second time.? When I encountered this kind of issue for the first time, the unit was totally locked up, any button on the HC screen was unresponsive, if I recall correctly.
I don't know if there is any clue in the log, but I put the ASCOM log file in User_Logs_error_files_and_suggestions folder of Files.
I'm afraid my Gemini-2 becoming faulty.
?
Thanks in advance,
?
masami
?
Hi masami,
?
Thanks for the log. A bit of a strange behavior from PHD2 -- it appears that at some point Gemini did not respond to a command to get simple RA/DEC position. After a few attempts to retransmit the request, the driver shut down the connection to Gemini. It then reported the connection closed to PHD2, yet it appears that PHD2 continued to try to guide for quite a while:

02:00:29.308 Disconnect() ? ? ? ? ? ? ?TID:13 [Exit]?
02:00:29.309 IT:Connected.Set ? ? ? ? ?TID:13 [Exit] False
02:00:29.310 IT:InterfaceVersion.Get ? TID:13 [Enter] 2
02:00:30.367 IT:PulseGuide5 ? ? ? ? ? ?TID:13 [Enter] guideWest, 1387
02:00:30.370 IT:CanPulseGuide.Get ? ? ?TID:13 [Enter] True
02:00:30.373 IT:PulseGuide5 ? ? ? ? ? ?TID:13 [Enter] guideSouth, 403
02:00:30.373 IT:CanPulseGuide.Get ? ? ?TID:13 [Enter] True
02:00:32.041 IT:PulseGuide5 ? ? ? ? ? ?TID:13 [Enter] guideEast, 251
02:00:32.042 IT:CanPulseGuide.Get ? ? ?TID:13 [Enter] True
02:00:32.048 IT:PulseGuide5 ? ? ? ? ? ?TID:13 [Enter] guideSouth, 1528
02:00:32.049 IT:CanPulseGuide.Get ? ? ?TID:13 [Enter] True
02:00:33.677 IT:PulseGuide5 ? ? ? ? ? ?TID:13 [Enter] guideEast, 973
02:00:33.677 IT:CanPulseGuide.Get ? ? ?TID:13 [Enter] True
02:00:33.682 IT:PulseGuide5 ? ? ? ? ? ?TID:13 [Enter] guideSouth, 2331
02:00:33.684 IT:CanPulseGuide.Get ? ? ?TID:13 [Enter] True
02:00:35.314 IT:PulseGuide5 ? ? ? ? ? ?TID:7 [Enter] guideEast, 2500
02:00:35.317 IT:CanPulseGuide.Get ? ? ?TID:7 [Enter] True
02:00:35.321 IT:PulseGuide5 ? ? ? ? ? ?TID:7 [Enter] guideSouth, 2500
02:00:35.322 IT:CanPulseGuide.Get ? ? ?TID:7 [Enter] True
02:00:36.954 IT:PulseGuide5 ? ? ? ? ? ?TID:7 [Enter] guideEast, 2500
02:00:36.955 IT:CanPulseGuide.Get ? ? ?TID:7 [Enter] True
02:00:36.960 IT:PulseGuide5 ? ? ? ? ? ?TID:7 [Enter] guideSouth, 2500
02:00:36.961 IT:CanPulseGuide.Get ? ? ?TID:7 [Enter] True
02:00:38.605 IT:PulseGuide5 ? ? ? ? ? ?TID:7 [Enter] guideEast, 2500
?
and so on... for quite a while. Looks like you tried to connect to Gemini from the driver at some point later, but Gemini didn't respond after multiple attempts. Did Gemini work after you rebooted it? Does the physical hand controller on Gemini work? Did you check that its IP address or other network settings didn't change for some reason? If you have different Ethernet cables, switch, or a different PC, can you try connecting them to Gemini using ASCOM driver and see if it can connect? I'm trying to eliminate any external reasons for failure before trying to diagnose Gemini.
?
Regards,
?
? -Paul
?


Re: PEC keeps turning off

 
Edited

On Fri, Feb 28, 2025 at 04:30 PM, Seokman Han wrote:
I actually updated to the new firmware and the software in January and noticed this PEC turning off problem. Last couple of nights I? got clear nights and both nights PEC appears to be off from looking at the PHD log file even though I had PEC checkbox was on. I don't know if this is a related issue or not, but the last couple of nights Gemini became unresponsive in the middle of night. It was disconnected from NINA, and I could not bring up the web page in the morning. I connected the hand controller, and the HC kept rebooting. I'm using 6.1 Gemini firmware. 1.1.28.0 Driver, 7.0.2 ASCOM Platform, and 3.1 HF2 NINA software. I will try to capture ASCOM log.
?
If PEC checkbox is on in the driver virtual hand-controller, then Gemini is reporting that PEC is being used. But, Gemini becoming unresponsive sounds like a bigger issue.?
?
If you use Ethernet to connect to Gemini, can you start Gemini.NET ASCOM driver, connect to the mount, and then go to Menu->Setup->Troubleshooting Report... Select all options in the list, and press Collect and Save button. Then, upload the resulting zip file to the Files section. This will include your ASCOM logs, as well as, a lot more information from Gemini.
?
?
Regards,
?
? -Paul


Re: PEC keeps turning off

 

I actually updated to the new firmware and the software in January and noticed this PEC turning off problem. Last couple of nights I? got clear nights and both nights PEC appears to be off from looking at the PHD log file even though I had PEC checkbox was on. I don't know if this is a related issue or not, but the last couple of nights Gemini became unresponsive in the middle of night. It was disconnected from NINA, and I could not bring up the web page in the morning. I connected the hand controller, and the HC kept rebooting. I'm using 6.1 Gemini firmware. 1.1.28.0 Driver, 7.0.2 ASCOM Platform, and 3.1 HF2 NINA software. I will try to capture ASCOM log.
?
Thank you,
Seokman
?


Re: Losmandy with ASI Air or Stellarmate pro will they work?

 

On Thu, Feb 13, 2025 at 03:32 AM, <drice34@...> wrote:
I might end up going with Stellarmate. Apparently, ASI AIR does not like long focal lengths when plate solving/polar aligning Next Star C8 (2000mm). I will eventually get a focal reducer.
Regardless I like what it has to offer and needed confirmation it would work with Gemeni 2.
?
I know the ASIAIR plate solves just fine on my M10" LX200 f/6.3 SCT which has significant coma at the outer edges.? While I have not personally tried it on the M8" LX200 f/10 ACF OTA but based on the calcs and ACF OTA's nice star shapes in the outer FOV I think it will be fine.? At some point I will try it but I have not tried this so far.??
?
--

Chip Louie Chief Daydreamer Imagination Hardware?

Astrospheric - South Pasadena, CA?


Gemini-2 partially locked-up!?

 

During my guiding session, suddenly PHD2 reported that the mount was not connected on the remote desktop screen.? Indeed the virtual HC's connect button showed "connect."??So I went to the roof and checked the status of the mount.? The unit was powered on and HC's menus were responsive, but the mount failed to move when I pressed the button.? After powering the unit again, it returned normal so far.
I remember this is the second time.? When I encountered this kind of issue for the first time, the unit was totally locked up, any button on the HC screen was unresponsive, if I recall correctly.
I don't know if there is any clue in the log, but I put the ASCOM log file in User_Logs_error_files_and_suggestions folder of Files.
I'm afraid my Gemini-2 becoming faulty.
?
Thanks in advance,
?
masami