¿ªÔÆÌåÓý

Re: bitx40 tuning range


 

Terry,

Do you mean the "scan range" that can be set in the SETTINGS menu?
The "scan range" that can be set in the SETTINGS menu is for frequency scanning mode:

Frequency Scan

1 short press - set frequency SCAN parameters (lower limit, upper limit, step size, step delay)

  • using the tuning pot, set the desired lower frequency scan limit
  • press the FB
  • using the tuning pot, set the desired upper frequency scan limit
  • press the FB
  • using the tuning pot, set the desired scan step size
  • press the FB
  • using the tuning pot, set the desired scan step delay (also used for A/B monitoring mode)
  • press the FB again to save the settings

It has nothing to do with the "fast step up/down" that will?occur when the end of the pot is reached.

73 Allard PE1NWL

Join [email protected] to automatically receive all group messages.