On Thu, Jun 2, 2022, 8:43 PM Nick Andrews via <nickjandrews=[email protected]> wrote:
So anybody seen these or know about them?? ?I got two of the sample units but no controller.?


 

¿ªÔÆÌåÓý

Its an Eberline radon working level meter. Basically a CAM. The detector faces the filter and counts alphas. Do you have a picture of the face of the instrumented. Does it look like this

https://www.ebay.com/itm/224877324911

patents

https://patents.google.com/patent/US4920263A/ru

Dud

?

From: [email protected] [mailto:[email protected]] On Behalf Of Nick Andrews
Sent: Thursday, June 2, 2022 6:43 PM
To: [email protected]
Subject: Alpha and Beta particle nuclear decay studies. Eberline RM units

?

So anybody seen these or know about them?? ?I got two of the sample units but no controller.?


 

No, all I got was the two sensor heads.? They were on a pallet of gear I bought at auction from NMSU.? Mostly Ludlum stuff but these were there and I thought they might be useful so i kept them...


On Thu, Jun 2, 2022, 10:02 PM Dude <dfemer@...> wrote:

Its an Eberline radon working level meter. Basically a CAM. The detector faces the filter and counts alphas. Do you have a picture of the face of the instrumented. Does it look like this

patents

Dud

?

From: [email protected] [mailto:[email protected]] On Behalf Of Nick Andrews
Sent: Thursday, June 2, 2022 6:43 PM
To: [email protected]
Subject: Alpha and Beta particle nuclear decay studies. Eberline RM units

?

So anybody seen these or know about them?? ?I got two of the sample units but no controller.?


 

No on the unit but I have that sensor in mt solid-state sensor collection. I see the PCB has a discriminator setting, but maybe the best approach to these surplus heads is to keep the sensor and charge coupled preamp, and substitute the electronics with a modular shaper block, then send that to a stand alone MCA.

For example the AMPTEK 8000D. It's set up for only external preamp/shaper heads already.

Later I'll show some of the CC preamp/shaper modules etc.

Also in my collection are flexible .s.s vacuum pipe for the small 25mm couplers, a manifold and electric-over-air relays.

And anything Dr. Prutchi used in his article is mine.


Geo

----- Original Message -----
From: Nick Andrews <nickjandrews@...>
To: [email protected]
Sent: Thu, 02 Jun 2022 21:42:50 -0400 (EDT)
Subject: Alpha and Beta particle nuclear decay studies. Eberline RM units

So anybody seen these or know about them?? ?I got two of the sample units but no controller.?




 

WLM = Working Level Meter (or Monitor). It outputs a number which is called the Working Level. A common term used in radon monitoring,

We can most likely get a manual if we don't have it already.

Geo

----- Original Message -----
From: Nick Andrews <nickjandrews@...>
To: [email protected]
Sent: Thu, 02 Jun 2022 21:51:08 -0400 (EDT)
Subject: Re: Alpha and Beta particle nuclear decay studies. Eberline RM units



On Thu, Jun 2, 2022, 8:43 PM Nick Andrews via <nickjandrews=[email protected]> wrote:
So anybody seen these or know about them?? ?I got two of the sample units but no controller.?




 

I'll have to check out Prutchi.? Has anyone bought his book?

I saw the value in these in the sensor more than anything else, which is why I kept them versus tossing on ebay for a C note or something.? Based on what I know now, I'd be kicking myself if I had!


On Fri, Jun 3, 2022 at 4:46 AM Geo Dowell <GEOelectronics@...> wrote:
No on the unit but I have that sensor in mt solid-state sensor collection. I see the PCB has a discriminator setting, but maybe the best approach to these surplus heads is to keep the sensor and charge coupled preamp, and substitute the electronics with a modular shaper block, then send that to a stand alone MCA.

For example the AMPTEK 8000D. It's set up for only external preamp/shaper heads already.

Later I'll show some of the CC preamp/shaper modules etc.

Also in my collection are flexible .s.s vacuum pipe for the small 25mm couplers, a manifold and electric-over-air relays.

And anything Dr. Prutchi used in his article is mine.


Geo

----- Original Message -----
From: Nick Andrews <nickjandrews@...>
To: [email protected]
Sent: Thu, 02 Jun 2022 21:42:50 -0400 (EDT)
Subject: Alpha and Beta particle nuclear decay studies. Eberline RM units

So anybody seen these or know about them?? ?I got two of the sample units but no controller.?




 

Same here nick. Probably have a dozen solid state sensors or so that way. 3 I are still? in working Pylon WLx radon meters. Saved for a rainy day. Others came from units I scrapped ou already? but saved the pumps, valves, fittings, filter holders? and piping stuff\.

Geo

----- Original Message -----
From: Nick Andrews <nickjandrews@...>
To: [email protected]
Sent: Fri, 03 Jun 2022 10:15:24 -0400 (EDT)
Subject: Re: Alpha and Beta particle nuclear decay studies. Eberline RM units

I'll have to check out Prutchi.? Has anyone bought his book?

I saw the value in these in the sensor more than anything else, which is why I kept them versus tossing on ebay for a C note or something.? Based on what I know now, I'd be kicking myself if I had!

On Fri, Jun 3, 2022 at 4:46 AM Geo Dowell <GEOelectronics@...> wrote:
No on the unit but I have that sensor in mt solid-state sensor collection. I see the PCB has a discriminator setting, but maybe the best approach to these surplus heads is to keep the sensor and charge coupled preamp, and substitute the electronics with a modular shaper block, then send that to a stand alone MCA.

For example the AMPTEK 8000D. It's set up for only external preamp/shaper heads already.

Later I'll show some of the CC preamp/shaper modules etc.

Also in my collection are flexible .s.s vacuum pipe for the small 25mm couplers, a manifold and electric-over-air relays.

And anything Dr. Prutchi used in his article is mine.


Geo

----- Original Message -----
From: Nick Andrews <nickjandrews@...>
To: [email protected]
Sent: Thu, 02 Jun 2022 21:42:50 -0400 (EDT)
Subject: Alpha and Beta particle nuclear decay studies. Eberline RM units

So anybody seen these or know about them?? ?I got two of the sample units but no controller.?









 

"I'll have to check out Prutchi.? Has anyone bought his book?:? I should have a signed copy in the library, and will find it when the stacks come upstairs to be sold on eBay. Not all but most.

Geo

----- Original Message -----
From: Nick Andrews <nickjandrews@...>
To: [email protected]
Sent: Fri, 03 Jun 2022 10:15:24 -0400 (EDT)
Subject: Re: Alpha and Beta particle nuclear decay studies. Eberline RM units

I'll have to check out Prutchi.? Has anyone bought his book?

I saw the value in these in the sensor more than anything else, which is why I kept them versus tossing on ebay for a C note or something.? Based on what I know now, I'd be kicking myself if I had!

On Fri, Jun 3, 2022 at 4:46 AM Geo Dowell <GEOelectronics@...> wrote:
No on the unit but I have that sensor in mt solid-state sensor collection. I see the PCB has a discriminator setting, but maybe the best approach to these surplus heads is to keep the sensor and charge coupled preamp, and substitute the electronics with a modular shaper block, then send that to a stand alone MCA.

For example the AMPTEK 8000D. It's set up for only external preamp/shaper heads already.

Later I'll show some of the CC preamp/shaper modules etc.

Also in my collection are flexible .s.s vacuum pipe for the small 25mm couplers, a manifold and electric-over-air relays.

And anything Dr. Prutchi used in his article is mine.


Geo

----- Original Message -----
From: Nick Andrews <nickjandrews@...>
To: [email protected]
Sent: Thu, 02 Jun 2022 21:42:50 -0400 (EDT)
Subject: Alpha and Beta particle nuclear decay studies. Eberline RM units

So anybody seen these or know about them?? ?I got two of the sample units but no controller.?